HANGZHOU ZETIAN TECHNOLOGY CO., LTD http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD "HANGZHOU ZETIAN TECHNOLOGY CO., Ltd is one of the leading manufacturers of environemental and industrial analysis instruments. With strong R&D capacity, we have developed various gas analyzers for continuous emission monitoring, process & safety control, ja-JP Background technology of dust particle measuring device(2021年) <p><a href="https://www.zetian-group.com/products/continuous-emission-monitoring-process-control/">https://www.zetian-group.com/products/continuous-emission-monitoring-process-control/</a></p> <p>The methods of dust particle measuring device mainly include optical analysis method and non-optical analysis method. Non-optical analysis method is difficult to monitor the dust concentration in real time because of its slow response speed and complex processing.</p> <p>For example, the existing chemical reaction dust concentration sensor needs to collect and process air dust, which has measurement delay difference and cannot be measured in real time. However, the safety of the electric dust concentration measuring device is poor. When the dust concentration in the mine is too high, a slight electric spark will cause the risk of mine explosion.</p> <p>The technology of this type of CEMS analyzer based on optical analysis has the characteristics of high detection sensitivity, strong selectivity and fast response, which is suitable for on-site real-time monitoring and low cost. It is an ideal method for dust concentration measurement in the future.</p> <p>However, the existing handheld dust concentration measuring devices must require operators to measure in the field, and in the environment similar to coal mines with high dust concentration, operators must take dust-proof measures during the measurement, otherwise the respiratory tract will be damaged and health will be affected.</p> <p>In addition, since the measuring instrument is located in the area of high dust, dust deposition must occur on the surface or inside the instrument after long-time use, which will affect the measurement accuracy.</p> <p>HANGZHOU ZETIAN TECHNOLOGY CO., LTD is committed to the integrity, strength and quality of our products. We're internationally recognized. Welcome you to visit us. Currently, we are looking for certificated distributor and OEM clients throughout the world. R&D cooperation is also welcomed. If you have any interest, please contact us!<br /> <a href="https://www.zetian-group.com/uploads/image/20190516/11/dms-100-ms-1000-dust-monitor_1557976417.png" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190516/11/dms-100-ms-1000-dust-monitor_1557976417.png" alt="dms-100-ms-1000-dust-monitor_1557976417.png" /></a><br /> <a href="https://www.zetian-group.com/uploads/image/20190516/11/dms-100-ms-1000-dust-monitor-2.png" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190516/11/dms-100-ms-1000-dust-monitor-2.png" alt="dms-100-ms-1000-dust-monitor-2.png" /></a><br /> <a href="https://www.zetian-group.com/uploads/image/20210413/15/cems.jpg" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20210413/15/cems.jpg" alt="cems.jpg" /></a><br /> <a href="https://www.zetian-group.com/uploads/image/20210413/15/dms-300-i.jpg" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20210413/15/dms-300-i.jpg" alt="dms-300-i.jpg" /></a></p> 2021-11-27T15:07:45+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/6y2Ty2JEwJ1 zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/6y2Ty2JEwJ1#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/6y2Ty2JEwJ1 What is a Gas Analyzer(2021年) <p><a href="https://www.zetian-group.com/products/gas-analyzers/">https://www.zetian-group.com/products/gas-analyzers/</a></p> <p>A physical online gas analyzer. According to the principle that different gases have different heat conductivity, the content of some components in the mixture can be calculated by measuring the thermal conductivity of the mixture.</p> <p>This kind of online gas analyzer is simple and reliable, suitable for many kinds of gas, and it is a basic gas analyzer equipment. However, it is difficult to directly measure the thermal conductivity of gas, so in fact, the change of thermal conductivity of gas is often converted into the change of electrical resistance, and then measured by electric bridge.</p> <p>There are two kinds of thermistor elements in the thermal online gas analyzers: semiconductor sensitive element and metal resistance wire. Semiconductor sensor has small volume, small thermal inertia and large resistance temperature coefficient, so it has high sensitivity and small time lag.</p> <p>The ball shaped metal oxide is sintered on the platinum coil as the sensing element, and then the same platinum coil with equal internal resistance and heat output is wound with the non-reactive material as the compensation element. These two components are used as two arms to form the bridge circuit, that is, the measuring circuit.</p> <p>When the semiconductor metal oxide sensing element absorbs the measured gas, the conductivity and thermal conductivity change, and the heat dissipation state of the element also changes. As the resistance of the platinum coil changes with the temperature change of the element, the bridge has an unbalanced voltage output, on which the concentration of gas can be detected.</p> <p>Thermal conductivity gas analyzer has a wide range of applications, in addition to being commonly used to analyze the content of hydrogen, ammonia, carbon dioxide, sulfur dioxide and low concentration of combustible gas, it can also be used as a detector in chromatographic analyzer to analyze other components.</p> <p><a href="https://www.zetian-group.com/uploads/image/20190516/11/lgt-106-by-pass-laser-gas-analyzer.png" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190516/11/lgt-106-by-pass-laser-gas-analyzer.png" alt="lgt-106-by-pass-laser-gas-analyzer.png" /></a><br /> <a href="https://www.zetian-group.com/uploads/image/20190523/09/lgt-180-extractive-laser-gas-analyzer-1.jpg" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190523/09/lgt-180-extractive-laser-gas-analyzer-1.jpg" alt="lgt-180-extractive-laser-gas-analyzer-1.jpg" /></a></p> 2021-11-27T15:07:22+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/HljUCo5dLb3 zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/HljUCo5dLb3#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/HljUCo5dLb3 Quick Start Guides to Equipment Operation(2021年) <p><a href="https://www.zetian-group.com/products/wdet-5000uvi-immersion-uv-water-analyzer/">https://www.zetian-group.com/products/wdet-5000uvi-immersion-uv-water-analyzer/</a></p> <p>Installation of equipment</p> <p>• The water quality testing instruments should be well grounded (the voltage between PE and N is less than 10VAC, and the voltage between L and PE shall be 220±22VAC), and connected with the equal potential of the digital acquisition instrument (the voltage between the digital acquisition instrument and the instrument housing should be about OV). Otherwise, it may lead to electrification of the instrument housing, abnormal operation and abnormal data transmission.</p> <p>• The power supply voltage range of the instrument is 220 ± 22VAC. When the voltage is unstable, it is recommended to install UPS or AC voltage regulator. Unstable input voltage is easy to burn out the power filter, resulting in abnormal power on of the instrument.</p> <p>• Three pipelines (water inlet pipe, water outlet pipe and overflow pipe) shall be installed for the pretreatment of the instrument. See the installation requirements in the user manual for details. Excessive water pressure may cause damage or leakage of water sample valve, which may lead to equipment failure.</p> <p>• The power supply of the sampling water pump shall be independent of the power supply of the equipment. See the wiring diagram in the user manual for details. Wiring errors will lead to uncontrollable sampling water pump and even burn out water pumps and circuit boards.</p> <p>Normal operation</p> <p>Before power:</p> <p>Check whether the peristaltic pump is pressed firmly; Check whether there is liquid in the digestion tube; Check whether the display screen is damaged or not.</p> <p>Start up:</p> <p>First, take a bottle of pure water (choose Wahaha or C'estbon bottled pure water, or pour out the zero sample delivered with the instrument), put all reagent tubes and zero sample tubes into it.</p> <p>Cleaning pipeline:</p> <p>Service bucket conventional bucket flushing; (Repeat this operation 3 times) Note: do not start the sample preparation, otherwise it will lead to cracking of the digestion tube. After rinsing, dry the reagent tube with paper towels and insert into the reagent. Note: Put the reagent tube about 1cm away from the bottom of the reagent bottle before sample action of the instrument (including calibration).</p> <p>Initial loading liquid:</p> <p>Service "normal" initial loading liquid (repeat this operation for 2 times), after which, prepare for testing.</p> <p>Calibration:</p> <p>First, the combined action measurement (six times of zero sample measurements and B times of standard sample measurements) shall be carried out: when the instrument is digested, do not open the door! After the combined action measurement is stable (the light intensity fluctuation of the last 3 sets of data is less than 200), the calibration is carried out. If it is unstable, the cause should be analyzed by multi parameter water analyzer and calibrated after stabilization.</p> <p>Measurements:</p> <p>The water sample is measured after the intermediate concentration standard sample of the test range meets the error of ± 10% (the table below is an example of COD, atmospheric nitrogen, total phosphorus and total nitrogen instrument range I).</p> <p>The test itemTest concentrationThe error meets ± 10%The test itemTest concentrationThe error meets ± 10%<br /> COD30mg/L27mg/L~33mg/LTP0.5mg/L0.45mg/L~0.55mg/L<br /> NH3-N0.5mg/L0.45mg/L~0.55mg/LTN2.5mg/L2.25mg/L~2.75mg/L</p> <p>Routine maintenance</p> <p>Reagents are prepared in strict accordance with the user's manual</p> <p>Regularly check the amount of waste liquid in the bottle to collect and treat in time to avoid the waste liquid overflow.</p> <p>Regularly check whether the reagent is discolored or turbid, if any, immediately remix the reagent and replace it. It is recommended to replace the whole set (including reagent bottle).</p> <p>Regularly check and tighten the connector (especially the connector connecting digestion module, channel valve and relief valve).</p> <p>Regularly check the sampling pretreatment, if it is found that the interior is dirty, it should be removed in time and washed with clean water.</p> <p>Clean the fluorine tube of the metering module regularly. If the cleaning is not clean, please replace it in time.</p> <p>Regularly check whether there is alarm on the online water analyzer, if so, please remove it in time, such as the timeout of sample injection water: check whether the sampling water pump is normal, check whether the pipeline (reagent pipe, hose, peristaltic pump pipe, etc.) leaks air, check whether the metering light intensity is normal, etc.</p> <p>Before the comparison and acceptance, the instrument should be debugged to ensure the accuracy of the intermediate concentration standard to improve the acceptance rate.</p> <p>Since long-term measurement of water sample may make pipes dirty, it is recommended to carry out zero sample measurement first if calibration is needed during maintenance, so as to improve the accuracy of measurement after calibration.</p> <p>If you want to know more information about air quality monitor, please contact us.</p> <p><a href="https://www.zetian-group.com/uploads/image/20190516/13/uv-water-quality-monitoring-analyzer_1557985441.png" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190516/13/uv-water-quality-monitoring-analyzer_1557985441.png" alt="uv-water-quality-monitoring-analyzer_1557985441.png" /></a><br /> <a href="https://www.zetian-group.com/uploads/image/20190516/13/uv-water-quality-monitoring-analyzer-installation.png" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190516/13/uv-water-quality-monitoring-analyzer-installation.png" alt="uv-water-quality-monitoring-analyzer-installation.png" /></a><br /> <a href="https://www.zetian-group.com/uploads/image/20190708/19/wdet-7000-integration-water-quality-online-analyzer.jpg" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190708/19/wdet-7000-integration-water-quality-online-analyzer.jpg" alt="wdet-7000-integration-water-quality-online-analyzer.jpg" /></a></p> 2021-11-27T15:06:57+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/eueiqRl4uIv zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/eueiqRl4uIv#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/eueiqRl4uIv Online Continuous Stack Emission Monitoring System(2021年) <p><a href="https://www.zetian-group.com/products/continuous-emission-monitoring-system/">https://www.zetian-group.com/products/continuous-emission-monitoring-system/</a></p> <p>CEMS refers to the device that continuously monitors the concentration and total emission of gaseous pollutants and particulate matter discharged by air pollution sources and transmits the information to the competent authorities in real time. It is known as the "automatic flue gas monitoring system", also known as the "continuous flue gas emission monitoring system" or "on-line flue gas monitoring system".</p> <p>EM-5 online continuous stack emission monitoring system (CEMS) is composed of gaseous pollutant monitoring subsystem, particulate matter monitoring subsystem, flue gas parameter monitoring subsystem and data acquisition, processing and communication subsystem.</p> <p>The gaseous pollutant monitoring subsystem is mainly used to monitor the concentration and total emission of gaseous pollutants such as SO2 and NOx. The particulate monitoring subsystem is mainly used to monitor the concentration and total emission of soot. The flue gas parameter monitoring subsystem is mainly used to measure flue gas velocity, flue gas temperature, flue gas pressure, flue gas oxygen content, flue gas humidity, etc., and it is used to calculate the total emission and convert the relevant concentrations. The data acquisition, processing and communication subsystem is composed of data collector and computer system. Various parameters are collected in real time to generate the dry base, wet base and converted concentration corresponding to each concentration value, generate the accumulated emission volume of day, month and year, complete the compensation of lost data and transmit the report to the competent department in real time.</p> <p>Em-5 online continuous stack emission monitoring system is applicable to the continuous exhaust gas emission monitoring of various boilers. The working principle of the CEMS monitoring system adopts the direct extraction method, which can continuously online monitor the concentration of particles, sulfur dioxide, nitrogen oxides, oxygen content, flue gas temperature, gas pressure, flue gas flow rate, flue gas humidity, and can also expand carbon monoxide and dioxide for specific occasions, measurement of carbon, humidity, hydrogen chloride, hydrogen fluoride, ammonia, hydrogen sulfide, chlorine and other parameters.</p> <p>The flue gas is extracted by the probe directly through electric heating. After the dedusting heating (120-180℃), heat preservation (greater than 120℃), the sample gas is guided to the pretreatment system, and then transported to the analyzer (ULTRAVIOLET Differential Optical Absorption Spectroscopy (DOAS)) for analysis and measurement by the sample gas control system.</p> <p>The measured data can be processed and stored by the control computer. It can connect with the computer of the superior environmental protection department through the network, and the environmental protection department can call the monitoring data conveniently and quickly.</p> <p>HANGZHOU ZETIAN TECHNOLOGY CO., LTD was established in 2008 and has a national wide impact in China now as a rapid development company in environmental protection and industrial process control. Our instruments can be customized by our professional staff who understand your compliance testing needs and provide you the best solutions.<br /> <a href="https://www.zetian-group.com/uploads/image/20190617/18/em-5-cd-continuous-emission-monitoring-system-cold-dry.jpg" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190617/18/em-5-cd-continuous-emission-monitoring-system-cold-dry.jpg" alt="em-5-cd-continuous-emission-monitoring-system-cold-dry.jpg" /></a><br /> <a href="https://www.zetian-group.com/uploads/image/20190708/20/em-5continuousemissionmonitoringsystemin-situ.png" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190708/20/em-5continuousemissionmonitoringsystemin-situ.png" alt="em-5continuousemissionmonitoringsystemin-situ.png" /></a></p> 2021-11-27T15:06:31+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/Tafg7XjIvYU zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/Tafg7XjIvYU#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/Tafg7XjIvYU Characteristics of Continuous Flue Gas Emission Monitoring System(2021年) <p><a href="https://www.zetian-group.com/products/air-quality-monitoring/">https://www.zetian-group.com/products/air-quality-monitoring/</a></p> <p>Technical characteristics</p> <p>1. The lower limit of measurement of ultraviolet flue gas analyzer is as low as mg/m', which is fully competent for the measurement technical index requirements of ultra-low emission monitoring occasions;</p> <p>2.The latest laser front scattering dust analyzer is applicable to high humidity flue gas, light leaking bacon, ultra-low dust emission and other application points;</p> <p>3. Integrated low flow temperature and pressure flow products solve the problem of inaccurate measurement of conventional products under ultra-low flue gas flow rate:</p> <p>4. The HCI type laser gas analyzer and HF analyzer have passed the national explosion-proof certification and are widely recognized in the industry;</p> <p>5. The ultraviolet differential absorption spectrum gas analysis technology with the company’s own property right is adopted to effectively avoid the interference of dust and moisture to the measurement:</p> <p>6. The gas flow path adopts multi-stage dust filtration technology combined with timing back blowing, which can effectively avoid dust blocking the filter and pipeline, as well as the measuring tank of pollution analyzer, and adapt to the most severe environment such as high dust, high humidity, high temperature and high corrosion;</p> <p>7. UV flue gas analyzer can simultaneously measure SO2, NO, NO2 (independent of NO), O2 humidity and other parameters, and can directly measure NO and NO2 to get NOX. NO NO2→NO converter is needed;</p> <p>8. Simple structure, no optical motion in the whole online continuous emission monitoring system, high reliability, long maintenance-free cycle, field vibration has no impact on measurement;</p> <p>9. Advanced ultraviolet differential absorption spectrum technology, spectral holographic grating spectrometry, diode array detection, obtain a complete continuous absorption spectrum, high wavelength resolution to ensure low detection limit, low temperature drifts and fast response time;</p> <p>10. The gas chamber of air quality monitoring instruments is processed by stainless pot, strong gas chamber, low cost, little affected by moisture and dust. The detector and gas chamber are connected by optical fiber, which is easy to replace and low in maintenance cost;</p> <p>11. The core modules and algorithms are completely independently developed, and the system has strong market competitiveness;</p> <p>12.The system has compact structure, high integration, convenient transportation and installation.</p> <p>We also have equipment for water quality testing, if you have needs ,contact us.</p> <p><a href="https://www.zetian-group.com/uploads/image/20190708/16/eqms-vocs-online-monitoring-system.jpg" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190708/16/eqms-vocs-online-monitoring-system.jpg" alt="eqms-vocs-online-monitoring-system.jpg" /></a><br /> <a href="https://www.zetian-group.com/uploads/image/20190617/18/ga-5000dn-denox-ammonia-slip-online-monitoring-system.jpg" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190617/18/ga-5000dn-denox-ammonia-slip-online-monitoring-system.jpg" alt="ga-5000dn-denox-ammonia-slip-online-monitoring-system.jpg" /></a><br /> <a href="https://www.zetian-group.com/uploads/image/20190516/11/lgt-100-cross-stack--in-situ-laser-gas-analyzer.png" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190516/11/lgt-100-cross-stack--in-situ-laser-gas-analyzer.png" alt="lgt-100-cross-stack--in-situ-laser-gas-analyzer.png" /></a><br /> <a href="https://www.zetian-group.com/uploads/image/20190523/09/em-5-flue-gas-analyzer-1.jpg" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190523/09/em-5-flue-gas-analyzer-1.jpg" alt="em-5-flue-gas-analyzer-1.jpg" /></a></p> 2021-11-27T15:06:07+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/69mZTA9wpUI zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/69mZTA9wpUI#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/69mZTA9wpUI Technical Advantages of Portable Systems(2021年) <p><a href="https://www.zetian-group.com/products/gas-analyzers/">https://www.zetian-group.com/products/gas-analyzers/</a></p> <p>The portable FTIR gas analyzer truly applies the principle of Fourier analysis to the on-line real-time analysis of field gases. Its solid and reliable interferometer, anti-corrosion sample gas chamber, long light path of multiple reflection, quick and convenient analysis software make the instrument have the characteristics of small volume, solid structure, strong seismic resistance, direct sampling, quick analysis and so on, it is an ideal tool for on-site rapid analysis.</p> <p>Portable heating sampling system</p> <p>Portable heating sampling system is specially designed for continuous gas emission monitoring, especially suitable for FT-2000P series portable FTIR gas analyzer, with built-in high temperature sampling pump, the whole process heat tracing sampling system is an ideal tool for accurate measurement of pollution components in high moisture content and strong corrosive gas emissions.</p> <p>The portable sampling system is composed of an integrated sampling tracing rod, a pre-treatment box with adjustable flow rate, a tracing tube and a temperature control module.</p> <p>The integrated sampling heat tracing probe rod contains a filter element, a pre-treatment box with a built-in heating sampling gas pump, which does not need to carry out complex pre-treatment processes such as dilution and dehydration of the sample gas. The sampling system and the gas chamber are heated at 180 ℃ throughout the whole process, and the sample gas will not have any condensation during the conduction process. The sample gas is directly connected to the gas analyzer equipment for analysis to realize non-destructive measurement.</p> <p>A built-in oxygen sensor (zirconia) enables the measurement of oxygen.</p> <p>The temperature and pressure flow interface is reserved for customers to choose, so as to realize the measurement of flue gas pressure, temperature, flow rate and other parameters.</p> <p>We also have air quality monitor for sale, if you have needs, please contact us.</p> <p><a href="https://www.zetian-group.com/uploads/image/20190708/19/ft-2000p-environmental-quality-monitoring-system.jpg" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190708/19/ft-2000p-environmental-quality-monitoring-system.jpg" alt="ft-2000p-environmental-quality-monitoring-system.jpg" /></a></p> 2021-11-27T15:05:40+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/CkS1GVhFblI zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/CkS1GVhFblI#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/CkS1GVhFblI Technical Advantages of Portable Systems(2021年07月23日) <p><a href="https://www.zetian-group.com/products/ft-2000p-portable-ftir-gas-analyzer/">https://www.zetian-group.com/products/ft-2000p-portable-ftir-gas-analyzer/</a><br /> <a href="https://www.zetian-group.com/products/gas-analyzers/">https://www.zetian-group.com/products/gas-analyzers/</a></p> <p>HANGZHOU ZETIAN TECHNOLOGY CO., LTD was established in 2008 and has a national wide impact in China now as a rapid development company in environmental protection and industrial process control. We focus on Ultra-violet DOAS gas analyzer, Laser TDLAS gas analyzer, air quality monitor, water quality testing<br /> , continuous emission monitoring system and etc, basically covering air pollution monitoring, metallurgical industries, chemical, refinery industries, cement, sulfur recovery, flue gas and other online monitoring needs.</p> <p>The portable FTIR gas analyzer truly applies the principle of Fourier analysis to the on-line real-time analysis of field gases. Its solid and reliable interferometer, anti-corrosion sample gas chamber, long light path of multiple reflection, quick and convenient analysis software make the instrument have the characteristics of small volume, solid structure, strong seismic resistance, direct sampling, quick analysis and so on, it is an ideal tool for on-site rapid analysis.</p> <p>Portable heating sampling system</p> <p>Portable heating sampling system is specially designed for continuous gas emission monitoring, especially suitable for FT-2000P series portable FTIR gas analyzer, with built-in high temperature sampling pump, the whole process heat tracing sampling system is an ideal tool for accurate measurement of pollution components in high moisture content and strong corrosive gas emissions.</p> <p>The portable sampling system is composed of an integrated sampling tracing rod, a pre-treatment box with adjustable flow rate, a tracing tube and a temperature control module.</p> <p>The integrated sampling heat tracing probe rod contains a filter element, a pre-treatment box with a built-in heating sampling gas pump, which does not need to carry out complex pre-treatment processes such as dilution and dehydration of the sample gas. The sampling system and the gas chamber are heated at 180 ℃ throughout the whole process, and the sample gas will not have any condensation during the conduction process. The sample gas is directly connected to the gas analyzer equipment for analysis to realize non-destructive measurement.</p> <p>A built-in oxygen sensor (zirconia) enables the measurement of oxygen.</p> <p>The temperature and pressure flow interface is reserved for customers to choose, so as to realize the measurement of flue gas pressure, temperature, flow rate and other parameters.<br /> <a href="https://www.zetian-group.com/uploads/image/20190708/18/eqms-3000benvironmentalqualitymonitoringsystem_1562581523.jpg" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190708/18/eqms-3000benvironmentalqualitymonitoringsystem_1562581523.jpg" alt="eqms-3000benvironmentalqualitymonitoringsystem_1562581523.jpg" /></a></p> 2021-07-01T16:50:17+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/Fh7hf4LJ9aU zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/Fh7hf4LJ9aU#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/Fh7hf4LJ9aU Characteristics of Continuous Flue Gas Emission Monitoring System(2021年07月19日) <p><a href="https://www.zetian-group.com/products/em-5-flue-gas-analyzer/">https://www.zetian-group.com/products/em-5-flue-gas-analyzer/</a><br /> <a href="https://www.zetian-group.com/products/gas-analyzers/">https://www.zetian-group.com/products/gas-analyzers/</a></p> <p>HANGZHOU ZETIAN TECHNOLOGY CO., LTD was established in 2008 and has a national wide impact in China now as a rapid development company in environmental protection and industrial process control. We focus on Ultra-violet DOAS gas analyzer, Laser TDLAS gas analyzer, air quality monitor, water quality testing<br /> , continuous emission monitoring system and etc, basically covering air pollution monitoring, metallurgical industries, chemical, refinery industries, cement, sulfur recovery, flue gas and other online monitoring needs.</p> <p>Technical characteristics</p> <p>1. The lower limit of measurement of ultraviolet flue gas analyzer is as low as mg/m', which is fully competent for the measurement technical index requirements of ultra-low emission monitoring occasions;</p> <p>2.The latest laser front scattering dust analyzer is applicable to high humidity flue gas, light leaking bacon, ultra-low dust emission and other application points;</p> <p>3. Integrated low flow temperature and pressure flow products solve the problem of inaccurate measurement of conventional products under ultra-low flue gas flow rate:</p> <p>4. The HCI type laser gas analyzer and HF analyzer have passed the national explosion-proof certification and are widely recognized in the industry;</p> <p>5. The ultraviolet differential absorption spectrum gas analysis technology with the company’s own property right is adopted to effectively avoid the interference of dust and moisture to the measurement:</p> <p>6. The gas flow path adopts multi-stage dust filtration technology combined with timing back blowing, which can effectively avoid dust blocking the filter and pipeline, as well as the measuring tank of pollution analyzer, and adapt to the most severe environment such as high dust, high humidity, high temperature and high corrosion;</p> <p>7. UV flue gas analyzer can simultaneously measure SO2, NO, NO2 (independent of NO), O2 humidity and other parameters, and can directly measure NO and NO2 to get NOX. NO NO2→NO converter is needed;</p> <p>8. Simple structure, no optical motion in the whole online continuous emission monitoring system, high reliability, long maintenance-free cycle, field vibration has no impact on measurement;</p> <p>9. Advanced ultraviolet differential absorption spectrum technology, spectral holographic grating spectrometry, diode array detection, obtain a complete continuous absorption spectrum, high wavelength resolution to ensure low detection limit, low temperature drifts and fast response time;</p> <p>10. The gas chamber of air quality monitoring instruments is processed by stainless pot, strong gas chamber, low cost, little affected by moisture and dust. The detector and gas chamber are connected by optical fiber, which is easy to replace and low in maintenance cost;</p> <p>11. The core modules and algorithms are completely independently developed, and the system has strong market competitiveness;</p> <p>12. The system has compact structure, high integration, convenient transportation and installation.<br /> <a href="https://www.zetian-group.com/uploads/image/20190708/17/vehicle-exhaust-remote-sensing-system.png" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190708/17/vehicle-exhaust-remote-sensing-system.png" alt="vehicle-exhaust-remote-sensing-system.png" /></a></p> 2021-07-01T16:46:51+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/QKnku8LDI7L zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/QKnku8LDI7L#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/QKnku8LDI7L Online Continuous Stack Emission Monitoring System(2021年07月15日) <p><a href="https://www.zetian-group.com/products/continuous-emission-monitoring-system/">https://www.zetian-group.com/products/continuous-emission-monitoring-system/</a><br /> <a href="https://www.zetian-group.com/products/continuous-emission-monitoring-system/">https://www.zetian-group.com/products/continuous-emission-monitoring-system/</a></p> <p>HANGZHOU ZETIAN TECHNOLOGY CO., LTD was established in 2008 and has a national wide impact in China now as a rapid development company in environmental protection and industrial process control. We focus on Ultra-violet DOAS gas analyzer, Laser TDLAS gas analyzer, air quality monitor, water quality testing<br /> , continuous emission monitoring system and etc, basically covering air pollution monitoring, metallurgical industries, chemical, refinery industries, cement, sulfur recovery, flue gas and other online monitoring needs.</p> <p>CEMS refers to the device that continuously monitors the concentration and total emission of gaseous pollutants and particulate matter discharged by air pollution sources and transmits the information to the competent authorities in real time. It is known as the "automatic flue gas monitoring system", also known as the "continuous flue gas emission monitoring system" or "on-line flue gas monitoring system".</p> <p>EM-5 online continuous stack emission monitoring system (CEMS) is composed of gaseous pollutant monitoring subsystem, particulate matter monitoring subsystem, flue gas parameter monitoring subsystem and data acquisition, processing and communication subsystem.</p> <p>The gaseous pollutant monitoring subsystem is mainly used to monitor the concentration and total emission of gaseous pollutants such as SO2 and NOx. The particulate monitoring subsystem is mainly used to monitor the concentration and total emission of soot. The flue gas parameter monitoring subsystem is mainly used to measure flue gas velocity, flue gas temperature, flue gas pressure, flue gas oxygen content, flue gas humidity, etc., and it is used to calculate the total emission and convert the relevant concentrations. The data acquisition, processing and communication subsystem is composed of data collector and computer system. Various parameters are collected in real time to generate the dry base, wet base and converted concentration corresponding to each concentration value, generate the accumulated emission volume of day, month and year, complete the compensation of lost data and transmit the report to the competent department in real time.</p> <p>Em-5 online continuous stack emission monitoring system is applicable to the continuous exhaust gas emission monitoring of various boilers. The working principle of the CEMS monitoring system adopts the direct extraction method, which can continuously online monitor the concentration of particles, sulfur dioxide, nitrogen oxides, oxygen content, flue gas temperature, gas pressure, flue gas flow rate, flue gas humidity, and can also expand carbon monoxide and dioxide for specific occasions, measurement of carbon, humidity, hydrogen chloride, hydrogen fluoride, ammonia, hydrogen sulfide, chlorine and other parameters.</p> <p>The flue gas is extracted by the probe directly through electric heating. After the dedusting heating (120-180℃), heat preservation (greater than 120℃), the sample gas is guided to the pretreatment system, and then transported to the analyzer (ULTRAVIOLET Differential Optical Absorption Spectroscopy (DOAS)) for analysis and measurement by the sample gas control system.</p> <p>The measured data can be processed and stored by the control computer. It can connect with the computer of the superior environmental protection department through the network, and the environmental protection department can call the monitoring data conveniently and quickly.<br /> <a href="https://www.zetian-group.com/uploads/image/20190708/16/eqms-vocs-online-monitoring-system.jpg" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190708/16/eqms-vocs-online-monitoring-system.jpg" alt="eqms-vocs-online-monitoring-system.jpg" /></a></p> 2021-07-01T16:46:19+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/mpabv5VNG4p zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/mpabv5VNG4p#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/mpabv5VNG4p Quick Start Guides to Equipment Operation(2021年07月10日) <p><a href="https://www.zetian-group.com/products/water-quality-analyzers/">https://www.zetian-group.com/products/water-quality-analyzers/</a><br /> <a href="https://www.zetian-group.com/products/wdet-7000-integration-water-quality-analyzer/">https://www.zetian-group.com/products/wdet-7000-integration-water-quality-analyzer/</a></p> <p>HANGZHOU ZETIAN TECHNOLOGY CO., LTD was established in 2008 and has a national wide impact in China now as a rapid development company in environmental protection and industrial process control. We focus on Ultra-violet DOAS gas analyzer, Laser TDLAS gas analyzer, air quality monitor, water quality testing<br /> , continuous emission monitoring system and etc, basically covering air pollution monitoring, metallurgical industries, chemical, refinery industries, cement, sulfur recovery, flue gas and other online monitoring needs.</p> <p>Installation of equipment</p> <p>• The water quality testing instruments should be well grounded (the voltage between PE and N is less than 10VAC, and the voltage between L and PE shall be 220±22VAC), and connected with the equal potential of the digital acquisition instrument (the voltage between the digital acquisition instrument and the instrument housing should be about OV). Otherwise, it may lead to electrification of the instrument housing, abnormal operation and abnormal data transmission.</p> <p>• The power supply voltage range of the instrument is 220 ± 22VAC. When the voltage is unstable, it is recommended to install UPS or AC voltage regulator. Unstable input voltage is easy to burn out the power filter, resulting in abnormal power on of the instrument.</p> <p>• Three pipelines (water inlet pipe, water outlet pipe and overflow pipe) shall be installed for the pretreatment of the instrument. See the installation requirements in the user manual for details. Excessive water pressure may cause damage or leakage of water sample valve, which may lead to equipment failure.</p> <p>• The power supply of the sampling water pump shall be independent of the power supply of the equipment. See the wiring diagram in the user manual for details. Wiring errors will lead to uncontrollable sampling water pump and even burn out water pumps and circuit boards.</p> <p>Normal operation</p> <p>Before power:</p> <p>Check whether the peristaltic pump is pressed firmly; Check whether there is liquid in the digestion tube; Check whether the display screen is damaged or not.</p> <p>Start up:</p> <p>First, take a bottle of pure water (choose Wahaha or C'estbon bottled pure water, or pour out the zero sample delivered with the instrument), put all reagent tubes and zero sample tubes into it.</p> <p>Cleaning pipeline:</p> <p>Service bucket conventional bucket flushing; (Repeat this operation 3 times) Note: do not start the sample preparation, otherwise it will lead to cracking of the digestion tube. After rinsing, dry the reagent tube with paper towels and insert into the reagent. Note: Put the reagent tube about 1cm away from the bottom of the reagent bottle before sample action of the instrument (including calibration).</p> <p>Initial loading liquid:</p> <p>Service "normal" initial loading liquid (repeat this operation for 2 times), after which, prepare for testing.</p> <p>Calibration:</p> <p>First, the combined action measurement (six times of zero sample measurements and B times of standard sample measurements) shall be carried out: when the instrument is digested, do not open the door! After the combined action measurement is stable (the light intensity fluctuation of the last 3 sets of data is less than 200), the calibration is carried out. If it is unstable, the cause should be analyzed by multi parameter water analyzer and calibrated after stabilization.</p> <p>Measurements:</p> <p>The water sample is measured after the intermediate concentration standard sample of the test range meets the error of ± 10% (the table below is an example of COD, atmospheric nitrogen, total phosphorus and total nitrogen instrument range I).</p> <p>The test itemTest concentrationThe error meets ± 10%The test itemTest concentrationThe error meets ± 10%<br /> COD30mg/L27mg/L~33mg/LTP0.5mg/L0.45mg/L~0.55mg/L<br /> NH3-N0.5mg/L0.45mg/L~0.55mg/LTN2.5mg/L2.25mg/L~2.75mg/L</p> <p>Routine maintenance</p> <p>Reagents are prepared in strict accordance with the user's manual</p> <p>Regularly check the amount of waste liquid in the bottle to collect and treat in time to avoid the waste liquid overflow.</p> <p>Regularly check whether the reagent is discolored or turbid, if any, immediately remix the reagent and replace it. It is recommended to replace the whole set (including reagent bottle).</p> <p>Regularly check and tighten the connector (especially the connector connecting digestion module, channel valve and relief valve).</p> <p>Regularly check the sampling pretreatment, if it is found that the interior is dirty, it should be removed in time and washed with clean water.</p> <p>Clean the fluorine tube of the metering module regularly. If the cleaning is not clean, please replace it in time.</p> <p>Regularly check whether there is alarm on the online water analyzer, if so, please remove it in time, such as the timeout of sample injection water: check whether the sampling water pump is normal, check whether the pipeline (reagent pipe, hose, peristaltic pump pipe, etc.) leaks air, check whether the metering light intensity is normal, etc.</p> <p>Before the comparison and acceptance, the instrument should be debugged to ensure the accuracy of the intermediate concentration standard to improve the acceptance rate.</p> <p>Since long-term measurement of water sample may make pipes dirty, it is recommended to carry out zero sample measurement first if calibration is needed during maintenance, so as to improve the accuracy of measurement after calibration.</p> <p><a href="https://www.zetian-group.com/uploads/image/20190527/14/dpm-6000-pm-monitor-pm2.5-pm10.png" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190527/14/dpm-6000-pm-monitor-pm2.5-pm10.png" alt="dpm-6000-pm-monitor-pm2.5-pm10.png" /></a></p> 2021-07-01T16:45:51+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/lC60ah9jWLy zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/lC60ah9jWLy#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/lC60ah9jWLy What is a Gas Analyzer(2021年07月07日) <p><a href="https://www.zetian-group.com/products/em-5-flue-gas-analyzer/">https://www.zetian-group.com/products/em-5-flue-gas-analyzer/</a><br /> <a href="https://www.zetian-group.com/products/gas-analyzers/">https://www.zetian-group.com/products/gas-analyzers/</a></p> <p>HANGZHOU ZETIAN TECHNOLOGY CO., LTD was established in 2008 and has a national wide impact in China now as a rapid development company in environmental protection and industrial process control. We focus on Ultra-violet DOAS gas analyzer, Laser TDLAS gas analyzer, air quality monitor, water quality testing<br /> , continuous emission monitoring system and etc, basically covering air pollution monitoring, metallurgical industries, chemical, refinery industries, cement, sulfur recovery, flue gas and other online monitoring needs.</p> <p>A physical online gas analyzer. According to the principle that different gases have different heat conductivity, the content of some components in the mixture can be calculated by measuring the thermal conductivity of the mixture.</p> <p>This kind of online gas analyzer is simple and reliable, suitable for many kinds of gas, and it is a basic gas analyzer equipment. However, it is difficult to directly measure the thermal conductivity of gas, so in fact, the change of thermal conductivity of gas is often converted into the change of electrical resistance, and then measured by electric bridge.</p> <p>There are two kinds of thermistor elements in the thermal online gas analyzers: semiconductor sensitive element and metal resistance wire. Semiconductor sensor has small volume, small thermal inertia and large resistance temperature coefficient, so it has high sensitivity and small time lag.</p> <p>The ball shaped metal oxide is sintered on the platinum coil as the sensing element, and then the same platinum coil with equal internal resistance and heat output is wound with the non-reactive material as the compensation element. These two components are used as two arms to form the bridge circuit, that is, the measuring circuit.</p> <p>When the semiconductor metal oxide sensing element absorbs the measured gas, the conductivity and thermal conductivity change, and the heat dissipation state of the element also changes. As the resistance of the platinum coil changes with the temperature change of the element, the bridge has an unbalanced voltage output, on which the concentration of gas can be detected.</p> <p>Thermal conductivity gas analyzer has a wide range of applications, in addition to being commonly used to analyze the content of hydrogen, ammonia, carbon dioxide, sulfur dioxide and low concentration of combustible gas, it can also be used as a detector in chromatographic analyzer to analyze other components.<br /> <a href="https://www.zetian-group.com/themes/simple/img/inner-banner-01.jpg" rel="nofollow"><img src="https://www.zetian-group.com/themes/simple/img/inner-banner-01.jpg" alt="inner-banner-01.jpg" /></a></p> 2021-07-01T16:45:18+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/oDXk8pKNZlZ zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/oDXk8pKNZlZ#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/oDXk8pKNZlZ Background technology of dust particle measuring device(2021年07月01日) <p><a href="https://www.zetian-group.com/products/ms-1000-dust-monitor/">https://www.zetian-group.com/products/ms-1000-dust-monitor/</a><br /> <a href="https://www.zetian-group.com/products/continuous-emission-monitoring-process-control/">https://www.zetian-group.com/products/continuous-emission-monitoring-process-control/</a></p> <p>HANGZHOU ZETIAN TECHNOLOGY CO., LTD was established in 2008 and has a national wide impact in China now as a rapid development company in environmental protection and industrial process control. We focus on Ultra-violet DOAS gas analyzer, Laser TDLAS gas analyzer, air quality monitor, water quality testing<br /> , continuous emission monitoring system and etc, basically covering air pollution monitoring, metallurgical industries, chemical, refinery industries, cement, sulfur recovery, flue gas and other online monitoring needs.</p> <p>The methods of dust particle measuring device mainly include optical analysis method and non-optical analysis method. Non-optical analysis method is difficult to monitor the dust concentration in real time because of its slow response speed and complex processing.</p> <p>For example, the existing chemical reaction dust concentration sensor needs to collect and process air dust, which has measurement delay difference and cannot be measured in real time. However, the safety of the electric dust concentration measuring device is poor. When the dust concentration in the mine is too high, a slight electric spark will cause the risk of mine explosion.</p> <p>The technology of this type of CEMS analyzer based on optical analysis has the characteristics of high detection sensitivity, strong selectivity and fast response, which is suitable for on-site real-time monitoring and low cost. It is an ideal method for dust concentration measurement in the future.</p> <p>However, the existing handheld dust concentration measuring devices must require operators to measure in the field, and in the environment similar to coal mines with high dust concentration, operators must take dust-proof measures during the measurement, otherwise the respiratory tract will be damaged and health will be affected.</p> <p>In addition, since the measuring instrument is located in the area of high dust, dust deposition must occur on the surface or inside the instrument after long-time use, which will affect the measurement accuracy.<br /> <a href="https://www.zetian-group.com/themes/simple/img/inner-banner-01.jpg" rel="nofollow"><img src="https://www.zetian-group.com/themes/simple/img/inner-banner-01.jpg" alt="inner-banner-01.jpg" /></a></p> 2021-07-01T16:44:42+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/vy9Eb8dP9h8 zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/vy9Eb8dP9h8#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/vy9Eb8dP9h8 The Detection and Analysis Methods of the SO2 Analyzer (2021年) <p><a href="http://www.zetian-group.com/products/em-5-flue-gas-analyzer/">http://www.zetian-group.com/products/em-5-flue-gas-analyzer/</a></p> <p>HANGZHOU ZETIAN TECHNOLOGY CO., LTD was established in 2008, and has national wide impact in China now as a fast-growing company specialized in environmental pollution monitoring and industrial process control. Our instruments and emission analyzers can be customized by our professional staff who understand your compliance testing needs and provide you best solutions. We focus on Ultra-violet DOAS gas analyzer, Laser TDLAS gas analyzer, online pollution monitoring system, etc, basically covering air pollution monitoring, metallurgical industries, chemical, refinery industries, cement, sulfur recovery, flue gas and other online air quality monitor needs. We also provide water quality testing. Our friendly and professional staff are always ready to provide technical support to our customers. </p> <p>Sulfur dioxide in the atmosphere is an important indicator of atmospheric environmental quality assessment. It is mainly derived from the oxidation of sulfur contained in the combustion of sulfur-containing fossil fuels when burning. Because of the widespread use of fossil fuels, sulfur dioxide is the main air pollutant.</p> <p>The so2 gas analyzer is suitable for the corrosion test of sulfur dioxide and hydrogen sulfide gas. The SO2 analyzer has the following functions: it can monitor the temperature, static pressure and the volume concentration and mass concentration of sulfur dioxide in the flue in real time; save the test data for a long time, and can check the test data at any time.</p> <p>The SO2 analyzer uses appropriate monitoring and analysis methods to do SO2 monitor and determinayion the sulfur dioxide content in the atmosphere.</p> <p>1. The dual optical path sulfur dioxide fluorescence detection method theoretically eliminates the measurement error of sulfur dioxide caused by the change of gas composition. Through experimental analysis, this method is significantly better than the single optical path detection method, and has a greatly improvement in selectivity, sensitivity, and anti-interference ability.</p> <p>2. In the determination of pararosaniline hydrochloride method, a porous glass absorption tube filled with potassium tetrachloromercury solution is used to collect sulfur dioxide in the atmosphere. During the sampling process, sulfur dioxide reacts with the absorption liquid to form a complex. In the sampled absorption solution, when formaldehyde and pararosaniline hydrochloride are added, a purple-red compound is formed. This compound has a strong absorption effect on visible light at 548 nm. Within a proper concentration range, the absorbance is linearly related to the concentration of sulfur dioxide. Therefore, by measuring the absorbance of the standard solution and the sample solution, the content of sulfur dioxide in the atmosphere can be determined. This method has  the advantages of high sensitivity, strong anti-interference ability, and stable after sample collection. The disadvantage is that the potassium mercury tetrachloride solution is more toxic.</p> <p>3.In the determination of SO2 analyzer methods, the UV fluorescence method is better. It uses 190nm-230nm ultraviolet light to excite sulfur dioxide molecules to emit fluorescence, and the fluorescence intensity is proportional to the concentration of sulfur dioxide. A SO2 monitoring equipment based on this principle was used in 1976. This method has high sensitivity, strong selectivity, simple operation, and is suitable for continuous automatic determination of sulfur dioxide in the atmosphere.</p> <p>We also provide online water quality analyzer,ftir gas analyzer ,continuous flue gas analyzer and so on.</p> <p><a href="https://www.zetian-group.com/uploads/image/20190708/19/am-5100so2analyzer.jpg" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190708/19/am-5100so2analyzer.jpg" alt="am-5100so2analyzer.jpg" /></a></p> 2021-04-28T17:20:43+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/iG3cL9us9IT zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/iG3cL9us9IT#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/iG3cL9us9IT Why do PM2.5 and PM10 Have "Upside-down Phenomenon"? (2021年) <p><a href="http://www.zetian-group.com/products/dpm-6000-pm-monitor-pm-2.5-pm-10/">http://www.zetian-group.com/products/dpm-6000-pm-monitor-pm-2.5-pm-10/</a></p> <p>HANGZHOU ZETIAN TECHNOLOGY CO., LTD was established in 2008, and has national wide impact in China now as a fast-growing company specialized in environmental pollution monitoring and industrial process control. Our instruments and emission analyzers can be customized by our professional staff who understand your compliance testing needs and provide you best solutions. We focus on Ultra-violet DOAS gas analyzer, Laser TDLAS gas analyzer, continuous emission monitoring system, etc, basically covering air pollution monitoring, metallurgical industries, chemical, refinery industries, cement, sulfur recovery, flue gas and other online air quality monitor needs. We also provide water quality testing. Our friendly and professional staff are always ready to provide technical support to our customers. </p> <p>1. What is the "Upside-down Penomenon" of PM2.5 and PM10?<br /> In the ambient air quality standard, PM10 is defined as the particulate matter in the ambient air with an aerodynamic equivalent diameter less than or equal to 10μm. PM2.5 is defined as the particulate matter in the ambient air with an aerodynamic equivalent diameter less than or equal to 2.5μm.</p> <p>By definition, PM2.5 is a part of PM10. So theoretically the concentration of PM10 measured at the same place and at the same time should be greater than PM2.5. However, in actual monitoring work, there will occasionally be a strange phenomenon where the concentration of PM2.5 is greater than the concentration of PM10, which is commonly known as "Upside-down Phenomenon".</p> <p>2. Why does the phenomenon appear?<br /> The mainly reason is that testing PM10 and PM2.5 uses different PM measuring devices.<br /> information to public authority to view.</p> <p>At present, the common particulate matter monitoring methods are mainly divided into two categories: oscillating balance method and β-ray method. With the advancement of technology, β-ray method instruments are divided into sampling tube constant temperature heating, dynamic heating, etc.; oscillation balance method instruments are further divided into simple oscillation balance method and oscillation balance method combined with membrane dynamic measurement system.</p> <p>1) Whether to use dynamic heating<br /> When dynamic heating is used, since the heating temperature can be automatically adjusted according to the relative humidity in the air, while preventing condensation in the sampling tube, it minimizes the loss of volatile components caused by the heating of the sampling tube. Thus when dynamic heating is used, the measured result will be higher than the constant temperature heating method.</p> <p>2) Whether to add membrane dynamic compensation system<br /> After the combined membrane dynamic compensation method, the sample gas dehumidification device is added without heating the sample at a high temperature. At the same time, the compensation system is used to compensate for the volatilization loss of volatile components. Therefore, the measured result of the oscillation balance method combined with the membrane dynamic compensation method  will be higher than the oscillatory balance method.</p> <p>In this way, at the same site, if only the PM2.5 monitoring equipment is equipped with a membrane dynamic compensation/dynamic heating system, but the PM10 is not installed, it will easily appear upside down.</p> <p>3. How to reduce "upside down"?<br /> Taking into account the differences between different methods, it is recommended that when choosing PM10 measurement device and PM2.5 measurement device, automatic pm monitor of the same principle should be used as much as possible. And based on the latest understanding of particle monitoring technology, at the same time, the use of oscillating balance and membrane dynamic compensation system method or the β-ray plus dynamic heating system method, as well  the simultaneous monitoring of PM10 and PM2.5 can effectively reduce the probability of the occurrence of upside-down phenomenon.</p> <p><a href="https://www.zetian-group.com/uploads/image/20190516/10/dpm-6000-pm-monitor-pm2.5-pm10.png" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190516/10/dpm-6000-pm-monitor-pm2.5-pm10.png" alt="dpm-6000-pm-monitor-pm2.5-pm10.png" /></a></p> 2021-04-28T17:20:11+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/SVNk42XxhCf zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/SVNk42XxhCf#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/SVNk42XxhCf Working Principles and Equipment of CEMS (2021年) <p><a href="http://www.zetian-group.com/products/em-5-flue-gas-analyzer/">http://www.zetian-group.com/products/em-5-flue-gas-analyzer/</a></p> <p>HANGZHOU ZETIAN TECHNOLOGY CO., LTD ,cems manufacturers,was established in 2008, and has national wide impact in China now as a fast-growing company specialized in environmental pollution monitoring and industrial process control. Our instruments and emission analyzers can be customized by our professional staff who understand your compliance testing needs and provide you best solutions. We focus on Ultra-violet DOAS gas analyzer, Laser TDLAS gas analyzer, continuous emission monitoring system, etc, basically covering air pollution monitoring, metallurgical industries, chemical, refinery industries, cement, sulfur recovery, flue gas and other online air quality monitor needs. We also provide water quality testing. Our friendly and professional staff are always ready to provide technical support to our customers. </p> <p>How to limit pollutant discharge is of great significance to environmental protection. Previous monitoring of industrial fume emissions adopted the conventional method of inserting a sampling head into a flue for sampling, which are analyzed in the laboratory to determine the amount of pollutants in fume. This method is time consuming and unavailable to provide long-term, continuous and systematic test data, so a more convenient and fast method than manual sampling is needed to accurately determine the pollutants in flue gas. In recent years, flue gas CEMS has developed to meet this demand that the emission and rate of pollutants in the flue gas can be easily detected through the system and the data results can be transmitted to the management department through DAS. The following will introduce the continuous emission monitoring system working principle and equipment of several kinds of CEMS.</p> <p>1. What kind of gas does high temperature gas analyzer detect?<br /> High temperature online gas analyzer, also called gas hygrometer or dew meter, is used for measuring humidity of fume in pollutant emission. Moisture concentration is transferred to dry gas concentration according to measured moisture. Besides, it can be applied in industrial online moisture monitoring.</p> <p>The principle can be proved by a simple experiment. If a polished metal surface is put in the air with relative humidity less than 100% and cooled, RH close to the surface will arrive at 100% with the temperature dropping to a certain value when there will be dew on the surface. It's because the moisture in the air reached saturation in this temperature that the water film adherent to the cold surface and moisture in the air stay in a dynamic balance. That is, the number of water molecules leaving in the unit time is equal to that returning to the surface.</p> <p>2. What is the accuracy of precision hygrometer?<br /> Precision humidity meter is an intelligent humidity/oxygen transmitter which starts with microprocessors as the core component and variable frequency icon oxygen sensor as measuring unit. It has simple structure and convenient installation and disassembly, which can measure the humidity of 300℃ fume, matching large or independent test system. The probe of precision hygrometer is equipped has thermal tracking to prevent the probe from being damaged by condensed water and affecting the measurement value, thus ensuring the measurement accuracy.</p> <p>3. How to measure the dust by dust particle monitor?<br /> Dust particle monitor is suitable for air sampling in industrial hygiene and occupational safety, which can live preview the dust concentration and record data. It can choose different ways for samplings based on different requirements, which is easy to carry and built in sampling pump.</p> <p>Dust particle monitor can measure the particle concentration and size as well as keep automatic recording. It's possible for the monitor with back reflection to real time read the mass concentration of aerosol. The special air circuit system isolated aerosol from optical chamber, ensures the cleaning of optical components, prolongs service life and reduces the maintenance expense.</p> <p><a href="https://www.zetian-group.com/uploads/image/20210315/09/cems-manufacturers.png" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20210315/09/cems-manufacturers.png" alt="cems-manufacturers.png" /></a></p> 2021-04-28T17:19:39+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/R4prQybH5r1 zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/R4prQybH5r1#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/R4prQybH5r1 How to Measure Air Pollution?(2021年) <p><a href="http://www.zetian-group.com/products/continuous-emission-monitoring-process-control/">http://www.zetian-group.com/products/continuous-emission-monitoring-process-control/</a></p> <p>HANGZHOU ZETIAN TECHNOLOGY CO., LTD ,cems analyzer manufacturers,was established in 2008, and has national wide impact in China now as a fast-growing company specialized in environmental pollution monitoring and industrial process control. Our instruments and emission analyzers can be customized by our professional staff who understand your compliance testing needs and provide you best solutions. We focus on Ultra-violet DOAS gas analyzer, Laser TDLAS gas analyzer, continuous emission monitoring system, etc, basically covering air pollution monitoring, metallurgical industries, chemical, refinery industries, cement, sulfur recovery, flue gas and other online air quality monitor needs. We also provide water quality testing. Our friendly and professional staff are always ready to provide technical support to our customers. </p> <p>There are many pollutions in the air, such as SO2, vehicle exhaust, PM, etc., which are harmful to human beings. So, it's of great necessity to have real time supervision on air pollution, usually using air pollution analyzer to test. Air pollution analyzer is rich in types based on the monitoring material. The below will introduce the working principle of SO2 analyzer, vehicle exhaust inspection equipment and PM monitor so that everyone can know how it measures air pollution.</p> <p>1. Continuous emission monitoring system working principle of SO2 analyzer</p> <p>Combined with micro process technology, SO2 analyzer adopts UV fluorescence to provide accurate and reliable SO2 detection in low concentration ppb~ppm, which can be applied in air monitoring and delamination CEMS.</p> <p>The principle of measuring SO2 is the molecules absorb energy from UV light, returning from high level to ground state, and fluoresce when UV around 220nm shines on SO2. The fluorescence intensity reflects the concentration of SO2. When the UV light intensity is constant at 220nm, the content of SO2 in the measured gas medium can be calculated by measuring the fluorescence intensity. This method can transport the gas medium for a long distance, without heating and heat preservation, easy to maintain and control. The key point of the technology is how to ensure the constant ultraviolet light intensity of 220nm, in addition, to prevent dust blockage and change in the balance release ratio.</p> <p>2. Working principle of vehicle exhaust inspection equipment</p> <p>Vehicle inspection equipment makes use of remote sensing technology for supervision.</p> <p>Monitoring by remote sensing of vehicle exhaust belongs to laboratory spectroscopy technology which is also called long path absorption spectroscopy. It can monitor the pollutants from vehicle emissions on the road. The working principle is sending ultraviolet and infrared light to optical mirror which will reflect to the detector across the road through light source. The cars have to go through these lights while driving on the road. Since the vehicle exhaust absorbs light, changing transmission light intensity, it can be monitored through the light intensity changes in inspection equipment, especially the concentration of oxynitride, hydrocarbon and CO.</p> <p>3. Working principle of PM monitor</p> <p>The principle of PM monitor is based on atmospheric particulate concentration technology and β-ray attenuation method. The monitor concentrates PM with aerodynamic equivalent diameter less than 2.5/10μm on rolling membrane filter. Taken low radiation 14C as active source, β-ray from the monitor goes through the polluted filter and received by the detector. PM measuring device, consisting of photomultiplier, plastic scintillator and counter, offers quantitative analysis on enrichment thickness of through β-ray from PM measuring system to calculate the PM2.5/10 in the air.<br /> <a href="https://www.zetian-group.com/uploads/image/20190708/18/eqms-3000benvironmentalqualitymonitoringsystem.jpg" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190708/18/eqms-3000benvironmentalqualitymonitoringsystem.jpg" alt="eqms-3000benvironmentalqualitymonitoringsystem.jpg" /></a></p> 2021-04-28T17:19:04+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/fhdkBmOPmUJ zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/fhdkBmOPmUJ#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/fhdkBmOPmUJ What is CEMS (Continuous Emission Monitoring System)? (2021年) <p><a href="https://www.zetian-group.com/products/lgt-100-cross-stack-in-situ-laser-gas-analyzer/">https://www.zetian-group.com/products/lgt-100-cross-stack-in-situ-laser-gas-analyzer/</a></p> <p>HANGZHOU ZETIAN TECHNOLOGY CO., LTD was established in 2008, and has national wide impact in China now as a fast-growing company specialized in environmental pollution monitoring and industrial process control. Our instruments and emission analyzers can be customized by our professional staff who understand your compliance testing needs and provide you best solutions. We focus on Ultra-violet DOAS gas analyzer, Laser TDLAS gas analyzer, continuous emission monitoring system, etc, basically covering air pollution monitoring, metallurgical industries, chemical, refinery industries, cement, sulfur recovery, flue gas and other online air quality monitor needs. We also provide water quality testing. Our friendly and professional staff are always ready to provide technical support to our customers. </p> <p>CEMS refers to the system,which include pm measuring device,which can monitor continuously the concentration and emission of gaseous pollutant and PM (particulate matter) in atmospheric pollution and transfer the</p> <p>CEMS cems monitoring system consists of four parts, dust monitor, gas pollutant monitor, flue gas parameter monitor and system control and DAS. It can have an online measurement of the concentration of SO2, NOx, CO, CO2 and PM, oxygen content, temperature and humidity and several gas parameters (such as pressure and flow).</p> <p>In order to protect the environment, local environmental protection authorities will, in light of local conditions and the requirements of the SEPA (State Environmental Protection Administration), set standards for the discharge of pollutants suitable for each region. Therefore, the environmental protection department will monitor the emission of fixed air source enterprises in real time. CEMS monitoring system can send measurement results to the environmental monitoring platform wirelessly or in other ways in time to meet the requirements of the environmental protection department and avoid unreasonable punishment by the environmental protection department.</p> <p>What Can a Portable Ftir Gas Analyzer Test?</p> <p>Portable FTIR gas analyzer is a gas testing system with accessibility, optional analysis component, lightweight and portable. The unique infrared spectroscope can detect many gases accurately in sequence in a single unit. Besides, with the special design, the portable FTIR gas analyzer wavelength generator can choose the wavelength in a rapid and accurate way. The portable ftir analyzer can continuously monitor all kinds of components in emission, such as SO2, NOx(NO, NO2), CH4, NH3, HCl, HF, CO, CO2, O2, H2O and so on. It can also be extended to the measurement of other components according to the actual requirement.</p> <p>Difference Between Laser Gas Analyzer and Extraction Analyzer</p> <p>Extraction analyzer has the function of dilution, solid phase extraction, heating, gas diffusion and dialysis. The more advanced laser gas analyzer comes up in the market due to the complex process and limited application.</p> <p>On the other hand, In-situ gas analyzer is a solid and durable process analyzer, which can realize stable measurement in severe environment of high temperature and pressure, active gas, irritant gas and high concentrations of dust. Because it can measure the gas in flue directly, it reduces the installation and maintenance costs. Rapid measuring protects interference from other gases, acquiring higher accuracy than other analyzers. It has been widely applied in continuous gas detection in industrial production process, emission monitoring of flue gas pollution sources, large space gas detection and environmental analysis.</p> <p><a href="https://www.zetian-group.com/uploads/image/20190617/18/ga-5000dn-denox-ammonia-slip-online-monitoring-system.jpg" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190617/18/ga-5000dn-denox-ammonia-slip-online-monitoring-system.jpg" alt="ga-5000dn-denox-ammonia-slip-online-monitoring-system.jpg" /></a><br /> <a href="https://www.zetian-group.com/uploads/image/20190617/18/em-5-cd-continuous-emission-monitoring-system-cold-dry.jpg" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190617/18/em-5-cd-continuous-emission-monitoring-system-cold-dry.jpg" alt="em-5-cd-continuous-emission-monitoring-system-cold-dry.jpg" /></a><br /> <a href="https://www.zetian-group.com/uploads/image/20190708/19/ft-2000p-environmental-quality-monitoring-system.jpg" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190708/19/ft-2000p-environmental-quality-monitoring-system.jpg" alt="ft-2000p-environmental-quality-monitoring-system.jpg" /></a><br /> <a href="https://www.zetian-group.com/uploads/image/20190516/11/lgt-100-cross-stack--in-situ-laser-gas-analyzer.png" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190516/11/lgt-100-cross-stack--in-situ-laser-gas-analyzer.png" alt="lgt-100-cross-stack--in-situ-laser-gas-analyzer.png" /></a></p> 2021-04-28T17:18:32+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/QQsI1vojU37 zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/QQsI1vojU37#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/QQsI1vojU37 How does Water Analyzer Equipment Test the Water? (2021年) <p><a href="http://www.zetian-group.com/products/codet-5000-codcr-online-automatic-analyzer/">http://www.zetian-group.com/products/codet-5000-codcr-online-automatic-analyzer/</a></p> <p>HANGZHOU ZETIAN TECHNOLOGY CO., LTD,cod analyzer manufacturers. was established in 2008, and has national wide impact in China now as a fast-growing company specialized in environmental pollution monitoring and industrial process control. Our instruments and emission analyzers can be customized by our professional staff who understand your compliance testing needs and provide you best solutions. We focus on Ultra-violet DOAS gas analyzer, Laser TDLAS gas analyzer, continuous emission monitoring system, etc, basically covering air pollution monitoring, metallurgical industries, chemical, refinery industries, cement, sulfur recovery, flue gas and other online air quality monitor needs. We also provide water quality testing. Our friendly and professional staff are always ready to provide technical support to our customers. </p> <p>Nowadays, environmental protection has caused public concerns where water pollution is an important environmental protection problem. It's necessary to test the water supplies for production and daily life to protect the water resources essential for human beings and secure drinking water hygiene. Water analyzer has a wide application in power station, waste water treatment plant, textile mill, pharmaceutical factory, environmental protection administration, epidemic prevention department and hospital. It can measure all kinds of water quality parameters, including organic pollutant, nutritive salt, metal and inorganic anions. The below will introduce how the water analyzer test the water quality.</p> <p>1. How to use ammonia analyzer to measure NH in waste water?</p> <p>Ammonia nitrogen in water mainly comes from catabolite of nitrogenous organic compound in sanitary sewage subjected to microbial action and industrial effluents, such as coking wastewater, ammonia fertilizer plant water and agricultural drainage. Besides, nitrite existing in water in oxygen free environment can revert to ammonia under microbial action. In aerobic environment, ammonia can transform to nitrite or even nitrate.</p> <p>It's beneficial to measure ammonia in various forms in water to assess the contaminated situation and natural cleaning. Higher content of ammonia gas will have toxic action on fish. Using ammonia analyzer, able to effectively monitor the ammonia content in water, has great influence on water monitoring. Ammonia analyzer tests ammonia by salicylic acid method which has simple operation and high sensitivity.</p> <p>2. How does total phosphorus analyzer test the phosphorus in water</p> <p>Total online cod analyzer mainly adopts rapid spectrophotometric method to measure total phosphorus in water, namely ammonium molybdate spectrophotometric method. Its treatment process is mainly divided into two steps:<br /> 1) Potassium persulfate is added to the water sample as an oxidant under neutral conditions, and the sample was continuously heated for 30 minutes at a constant temperature of 125 ° C. All the phosphorus in the water sample is converted into phosphate salts;<br /> 2) The water sample, which was previously formed orthophosphate, was reacted with ammonium molybdate and antimony tartrate potassium oxide in the acidic medium to form molybdophosphate heteropoly acid, which was reduced by reducing agent ascorbic acid and finally turned into a blue complex.</p> <p>After the above two steps, the physical colorimetric method is used to obtain a transmittance of the water sample, and then the microcomputer technology is used to analyze and calculate the transmittance, finally getting the total phosphorus content in the water sample.</p> <p>3. How does new generation toc test nitrogen in water?</p> <p>Total nitrogen is an important index of water detection with complex measurement and easy to cause deviation. New generation toc applies KPS UV spectrophotometric to test the nitrogen in water.</p> <p>New generation toc takes KPS as the oxidant to digest water in high temperature and pressure with color matching of 210nm and 228nm double wavelength UV. It has high range and low range, which can be accurately measured as 0.5-150mg/L N. The device is composed of automatic sampler, analysis unit and controller. Without any need of artificial interference for the whole analysis, the analyzer can automatically finish sample introduction, digestion, cooling, color matching and drainage. It can save the analysis result automatically which can be referred by users through the controller.<br /> <a href="https://www.zetian-group.com/uploads/image/20210311/10/water-analyzer-instrument.png" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20210311/10/water-analyzer-instrument.png" alt="water-analyzer-instrument.png" /></a></p> 2021-04-28T17:17:55+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/IocyNZAKKj4 zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/IocyNZAKKj4#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/IocyNZAKKj4 Working Principle of Flue Gas Analyzer(2021年) <p><a href="http://www.zetian-group.com/products/em-5-flue-gas-analyzer/">http://www.zetian-group.com/products/em-5-flue-gas-analyzer/</a></p> <p>HANGZHOU ZETIAN TECHNOLOGY CO., LTD ,air pollution monitoring instruments manufacturers,was established in 2008, and has national wide impact in China now as a fast-growing company specialized in environmental pollution monitoring and industrial process control. Our instruments and emission analyzers can be customized by our professional staff who understand your compliance testing needs and provide you best solutions. We focus on Ultra-violet DOAS gas analyzer, Laser TDLAS gas analyzer, online stack monitoring system, etc, basically covering air pollution monitoring, metallurgical industries, chemical, refinery industries, cement, sulfur recovery, flue gas and other online air quality monitor needs. We also provide water quality testing. Our friendly and professional staff are always ready to provide technical support to our customers. </p> <p>Flue gas analyzer is a kind of equipment adopting electrochemical sensor to continuously analyze and measure the content of SO2, NO, NO2, O2, NH3, Cl2, O3, H2S, Ch3 in exhaust gas. It is mainly applied in the pollutant discharge of small oil burning boiler and the environmental monitoring near the pollution sources. According to the mode of occupation, it can be divided into portable flue gas analyzer and fixed wired recording flue gas analyzer. Hangzhou Zetian Technology Co., Ltd., a producer and seller of flue gas analyzer, is an intelligent environmental protection enterprise providing professional solutions for the monitoring in polluter gas, polluter water, mobile source, ambient air, surface water, VOCs and raise dust. Welcome to order.</p> <p>1. How fast is the online gas analyzer?<br /> Online gas analyzer makes use of induction condensation method. Its working principle is to measure the content of SO2, NO, NO2 in flue gas by UV-DOAS, with wet oxygen content by electrochemistry, and calculate the dry flue gas concentration of SO2, NO, NO2 through dryness transformation. Without UV absorbing water and undistributed by water and dust, LOD of SO2, NO, NO2 can reach 1mg/m3 (15m optical path).</p> <p>2. What should flue gas analyzer on sale be?<br /> As a flue gas analyzer supplier, Hangzhou Zetian Technology Co., Ltd. sells flue gas analyzer whose technical requirements on function design, structure, performance, installation and test conform to the relevant standard requirement of environmental protection. In the meanwhile, the flue gas analyzer has the following features:</p> <p>Automatic sampling, analyzation and test, fast measuring speed. No any consumables.</p> <p>Simple operation. It can be operated and used after on-site training.</p> <p>Widely applied in online environment monitoring, IPC and safety monitoring.</p> <p>Adopting adaptive spectrum technology, maintenance free and long period.</p> <p>Based on UV-DOAS and chemometrics algorithms, the analyzer has high measurement accuracy and reliability.<a href="https://www.zetian-group.com/uploads/image/20190516/11/lgt-100-cross-stack--in-situ-laser-gas-analyzer.png" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190516/11/lgt-100-cross-stack--in-situ-laser-gas-analyzer.png" alt="lgt-100-cross-stack--in-situ-laser-gas-analyzer.png" /></a></p> 2021-04-28T17:17:21+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/n3i3cQXhYMk zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/n3i3cQXhYMk#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/n3i3cQXhYMk ZETIAN Technology Brings You the EM-5 Flue Gas Analyser(2021年) <p><a href="https://www.zetian-group.com/products/em-5-online-flue-gas-analyzer/">https://www.zetian-group.com/products/em-5-online-flue-gas-analyzer/</a></p> <p>HANGZHOU ZETIAN TECHNOLOGY CO., LTD,air quality monitoring equipment suppliers, was established in 2008, and has national wide impact in China now as a fast-growing company specialized in environmental pollution monitoring and industrial process control. Our instruments and emission analyzers can be customized by our professional staff who understand your compliance testing needs and provide you best solutions. We focus on Ultra-violet DOAS gas analyzer, Laser TDLAS gas analyzer, , etc, basically covering air pollution monitoring, metallurgical industries, chemical, refinery industries, cement, sulfur recovery, flue gas and other online air quality monitor needs. We also provide water quality testing. Our friendly and professional staff are always ready to provide technical support to our customers. <br /> EM-5 flue gas analyzer adopts ultraviolet differential optical absorption spectroscopy (DOAS) technology, which can measure the concentration of SO2, NO, NO2, NH3, H2S, CI2, HCI and other gases, with high measurement accuracy, good reliability and fast response and other characteristics. The EM-5 flue gas analyser is a key system for online gas analyser, which can be widely used in thermal power plants, waste incineration plants, chlor-alkali plants, industrial boilers and furnaces, etc., for online monitoring and process control such as desulfurization and out-of-stock<br /> so2 analyzer<br /> 1. Working principle</p> <p>The working principle of EM-5 flue analyser is based on Lambert-Beer law, and its analysis method belongs to ultraviolet absorption spectroscopy.</p> <p>The measurement unit of the flue gas analyser is composed of components such as a light source, a gas chamber, an optical fiber, and a spectrometer. The ultraviolet light emitted by the light source enters the gas chamber through the optical window, and is absorbed by the sample gas flowing through the gas chamber. The light carrying the absorption information of the sample gas is converged by the lens and then coupled into the optical fiber, and sent to the spectrometer through the optical fiber for spectroscopy processing, then you can get the gas absorption spectrum.</p> <p>Through differential analysis of the spectrum, combined with chemometric algorithms, the concentration of related components in the gas can be obtained.</p> <p>2. System Features</p> <p>1) Using ultraviolet spectrum analysis technology and differential absorption spectrum algorithm, it is the most accurate online analysis method for Cl2 gas at present. Compared with non-spectroscopic infrared analyzers, it has no cross interference, which is not affected by smoke, dust, and moisture, and has a small temperature drift. Etc;</p> <p>2) Utilizing the different absorption strength of gas in different bands, it can realize automatic range switching, large dynamic range, non-dispersive infrared technology and non-dispersive ultraviolet technology;</p> <p>ZETIAN Technology is selling flue gas analyzers. Welcome to buy.<br /> <a href="https://www.zetian-group.com/uploads/image/20190523/09/em-5-flue-gas-analyzer-1.jpg" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190523/09/em-5-flue-gas-analyzer-1.jpg" alt="em-5-flue-gas-analyzer-1.jpg" /></a></p> 2021-04-28T17:16:46+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/mf2zV11NSI6 zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/mf2zV11NSI6#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/mf2zV11NSI6 WDet-5000UVI Immersion UV Water Analyzer(2020年11月23日) <p><a href="http://www.folkd.com/detail/%2Fwww.zetian-group.com%2Fproducts%2Fwdet-5000uvi-immersion-uv-water-analyzer">http://www.folkd.com/detail//www.zetian-group.com/products/wdet-5000uvi-immersion-uv-water-analyzer</a></p> <p>Overview of Portable Water Quality Analyzer<br /> WDet-5000UVI is the first full-spectrum (200-800nm) immersion UV water analyzer at home. With features of the delicate and convenient structure, plug and play, auto cleaning function, it can be widely applied to measure indexes including COD, BOD, and turbidity in surface water, underground water, and municipal sewage.<br /> Technical Principle Of WDet-5000UVI Immersion UV Water Analyzer<br /> The analyzer adopts a pulse xenon lamp as the light source and ultraviolet spectrometer as a detector, which can collect the absorption spectrum of water pollution between 200nm and 800nm in real time. The water pollutant content can be analyzed in real time through the chemometrics algorithm technology. The optical path is shown as the following figure.<br /> The spectral probe can record a complete spectrum between 200nm to 800nm (UV-visible light) and distinguish the spectrum into 256 wavelengths to obtain "Spectral fingerprint". It can monitor multiple parameters simultaneously through the information contained in spectral fingerprint and compensate those parameters aiming at possible cross-sensitivity. The relevance between measuring result and laboratory result achieves high quality that simple optical instrument can never obtain before.<br /> Features Of WDet-5000UVI Immersion UV Water Analyzer<br /> Adopt a full spectrum (200-800nm) (UV-visible light) measurement technology and chemometrics algorithm. Compared with dual wavelength background deduction technology, it can measure more parameters and be less affected by composition change of sewage.<br /> Use high-pressure gas to clean probe automatically, or employ immersion electrical brush to clean.<br /> Not required for reagent preparation; save operating cost and no secondary pollution.<br /> Fast response time(about 2s), applied to occasions with high requirements for real-time.<br /> Without interference by chloride.<br /> Technical Specification Of WDet-5000UVI Immersion UV Water Analyzer<br /> Measuring MethodUV/visible light DOAS, wavelength range: 200-800nm<br /> Power supply12VDC<br /> Linearity2%F.S.<br /> Zero drift<1%F.S.<br /> Range(COD)0~50~200mg/L, larger range is customizable<br /> Measurement intervalMinimum 60s, period can be set<br /> Probe immersion depth<10m<br /> Optical pathAdjust according to actual working condition<br /> Water temp requirement5℃~45℃<br /> Probe IP gradeIP68<br /> Cleaning methodGas purging or immersion electric brush<br /> Auto cleaning periodExternal control<br /> External interfaceRS232, MODBUS protocol<br /> Probe dimensionΦ60mm×380.5mm<br /> Probe weight<3kg<br /> Auto compensation of cross sensitivityTurbidity/organicsubstance<br /> Measuring range of Integrated temp-10℃~50℃<br /> Temperature sensor resolution0.1℃<br /> <a href="https://www.zetian-group.com/uploads/image/20190516/13/uv-water-quality-monitoring-analyzer.png" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190516/13/uv-water-quality-monitoring-analyzer.png" alt="uv-water-quality-monitoring-analyzer.png" /></a><br /> <a href="https://www.zetian-group.com/uploads/image/20190516/13/uv-water-quality-monitoring-analyzer-installation.png" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190516/13/uv-water-quality-monitoring-analyzer-installation.png" alt="uv-water-quality-monitoring-analyzer-installation.png" /></a></p> 2020-11-09T11:04:49+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/bVnH0gEmuEN zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/bVnH0gEmuEN#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/bVnH0gEmuEN Water Quality Analyzers(2020年11月22日) <p><a href="http://www.folkd.com/detail/%2Fwww.zetian-group.com%2Fproducts%2Fwater-quality-analyzers">http://www.folkd.com/detail//www.zetian-group.com/products/water-quality-analyzers</a></p> <p>Hangzhou Zetian Technology Co., Ltd. is the only company in China that has five analytical technology platforms including LED colorimetric platform, full-spectrum colorimetric platform, cold atomic absorption colorimetric platform, anode dissolution platform and electrode method platform. These five kinds of analysis platform can measure the common pollution factors in water, including COD, ammonia nitrogen, total phosphorus, total nitrogen and heavy metals such as copper, chromium, lead, zinc, mercury, arsenic, etc. At the same time, using the full spectrum colorimetric platform or anodic dissolution platform also can realize COD/ ammonia nitrogen integrated system, total phosphorus/ total nitrogen integrated system, and all kinds of heavy metal integrated system, etc.<br /> The water quality analyzer equipment of ZETIAN have been experienced years of on-site validation, stable and reliable, low failure rate. Product details are listed below.<br /> Peristaltic Pump Tube:<br /> The United States imported special rubber hose, long service life, a tube can use more than one year.<br /> Sample Module:<br /> Homemade sampling module uses the high pure PTFE material, disassembly easy to clean or replace, reliable operation, every channel is completely isolated.<br /> Control System:<br /> (1) Control solenoid valve uses non-contact electronic switch, no mechanical life.<br /> (2) Homemade control unit, after years of verification, low fault rate, high reliability, modular design, low maintenance cost.<br /> Instrument Protection-Grounding Design:<br /> Instruments have high-level intelligence, such as reagents fault adding warning (especially H2SO4 used in COD, if it is not H2SO4, it is likely to lead digestion tube burst), leakage protection (if there is a leak, the instrument will report en error), pressure relief valve (making pressure in digestion tube within a certain range).<br /> All the external interface and main circuit of equipment is in isolation, which makes the normal sample without the outside interference. Especially for unequal potential connection, its effect is particularly evident.<br /> In analog circuits (measurement module) also made electrical isolation, which makes the minimum possible interference on measurement.<br /> Measuring Parts:<br /> Modulating optical measurement makes no influence of external light on measurement, it is more stable.<br /> External Interface:<br /> The largest configuration has 2×4-20 mA output, 4×4-20 mA input, 2 switch input, 2 switch output, can access the PH meter, flow meter, ss and other equipment, and can display on the main interface.<br /> Technology Platform:<br /> It has five measuring platforms, suitable for the needs of different applications.</p> <p><a href="https://www.zetian-group.com/uploads/image/20190708/19/codet-5000codcrwaterqualityonlineautomaticanalyzer.jpg" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190708/19/codet-5000codcrwaterqualityonlineautomaticanalyzer.jpg" alt="codet-5000codcrwaterqualityonlineautomaticanalyzer.jpg" /></a><br /> <a href="https://www.zetian-group.com/uploads/image/20190708/19/wdet-5000-total-phosphorus-online-automatic-analyzer.jpg" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190708/19/wdet-5000-total-phosphorus-online-automatic-analyzer.jpg" alt="wdet-5000-total-phosphorus-online-automatic-analyzer.jpg" /></a><br /> <a href="https://www.zetian-group.com/uploads/image/20190516/13/uv-water-quality-monitoring-analyzer.png" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190516/13/uv-water-quality-monitoring-analyzer.png" alt="uv-water-quality-monitoring-analyzer.png" /></a></p> 2020-11-09T11:04:17+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/zjVPoK9otpd zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/zjVPoK9otpd#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/zjVPoK9otpd DMS-100/MS-1000 Dust Monitor(2020年11月21日) <p><a href="http://www.folkd.com/detail/%2Fwww.zetian-group.com%2Fproducts%2Fms-1000-dust-monitor">http://www.folkd.com/detail//www.zetian-group.com/products/ms-1000-dust-monitor</a></p> <p>Overview<br /> DMS-100/MS-1000 is a self-developed online dust analysis product and a dust particle measuring device, adopting laser backward scattering measuring technology with imported core components. It is mainly used for continuous monitoring of PM emission concentrations of various pollution sources. It can be not only matched with CEMS but also be used separately or together with multiple dust monitors to form a dust monitoring network, sharing the same data collection and processing background.<br /> Principle Of DMS-100/MS-1000 Dust Monitor<br /> DMS-100/MS-1000 dust monitor consists of the optical part, circuit and signal processing part, calibrator and air curtain protection part.</p> <p>The laser beam (650nm) emitted by semiconductor laser enters the stack and produces scattering light by interaction with dust particles. The backscattered light enters the photosensitive detector through the convergence of the lens. The signal processing circuit converts the light signal into a standard signal in proportion to dust concentration and output, thus dust particle emission concentration of pollution source is obtained.<br /> Features Of DMS-100/MS-1000 Dust Monitor<br /> •Support online zero and span calibration<br /> •Automatic gain control function and temperature compensation<br /> •Convenient for installation, disassembly and cleaning with small and compact structure<br /> •Able to eliminate the influence of background stray light<br /> Specification Of DMS-100/MS-1000 Dust Monitor<br /> Measuring principleLaser backward scattering<br /> Measuring range0~200mg/m3, 0~10g/m3 (customizable)<br /> Indication error≤±20%<br /> Indication repeatability10%<br /> Laser device650nm<br /> Medium temperature<300℃<br /> Ambient Temperature-20~+45℃<br /> Stack diameter≥0.5m<br /> Analog output4-20mA, maximum load 800Ω<br /> COMM interfaceRs485, 2 ×relay output, bluetooth<br /> HMIIPC, APP(for MS-1000)<br /> Weight4kg<br /> Power<3W<br /> Dimension158mm* 158mm*234mm (square)<br /> 158mm* 158mm*273mm (circular)<br /> Supply voltage24VDC±10%<br /> Installation Of DMS-100/MS-1000 Dust Monitor<br /> 1. The instrument is installed on the stack by flange<br /> 2. The rain cover will be installed at the back end of the monitor<br /> 3. Power and gas source is connected at the back end of the monitor</p> <p><a href="https://www.zetian-group.com/uploads/image/20190516/11/dms-100-ms-1000-dust-monitor_1557976417.png" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190516/11/dms-100-ms-1000-dust-monitor_1557976417.png" alt="dms-100-ms-1000-dust-monitor_1557976417.png" /></a><br /> <a href="https://www.zetian-group.com/uploads/image/20190516/11/dms-100-ms-1000-dust-monitor-2.png" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190516/11/dms-100-ms-1000-dust-monitor-2.png" alt="dms-100-ms-1000-dust-monitor-2.png" /></a></p> 2020-11-09T11:03:45+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/5JGsaRgzOiT zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/5JGsaRgzOiT#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/5JGsaRgzOiT LGT-100 Cross Stack & In-Situ Laser Gas Analyzer(2020年11月20日) <p><a href="http://www.folkd.com/detail/%2Fwww.zetian-group.com%2Fproducts%2Flgt-100-cross-stack-in-situ-laser-gas-analyzer">http://www.folkd.com/detail//www.zetian-group.com/products/lgt-100-cross-stack-in-situ-laser-gas-analyzer</a></p> <p>Overview<br /> LGT-100 in-situ gas analyzer is a flameproof in situ gas analyzer for industrial online analysis and environmental on-line monitoring, which can online analyze O2, CO, NH3, CO2, CH4, H2O, HCl, HF and other gases in various complex conditions (NOTE: A single analyzer can only analyze 1~2 components). Measuring concentration range from major to trace.<br /> Features Of LGT-100 Cross Stack & In-Situ Laser Gas Analyzer<br /> • Easy optical path adjusting, XY direction non-coupling adjusting.<br /> • Small drift, long maintenance period, drift ≤ 1%F.S./half year.<br /> • "Single line" spectrum technology, free from the interference of background gas.<br /> • Integrated structure design, high stability, and reliability.<br /> • Integrated flameproof structure, consuming less purge gas compared with positive-pressure mode.<br /> • In-situ measurement without a pretreatment system avoids adsorption, blockage, and damage reduces cost.<br /> Technical Parameter Of LGT-100 Cross Stack & In-Situ Laser Gas Analyzer<br /> PrincipleTDLAS<br /> Linearity Error≤±1%F.S.<br /> Span Drift≤±1% F.S./half year<br /> Zero Drift≤±1% F.S./half year<br /> Calibration cycle2 times/year<br /> Response Time≤1s(T90)<br /> Explosion proofExdIICT6 Gb<br /> Analog Output2× 4-20mA output<br /> Analog Input   2× 4-20mA input<br /> Digital CommunicationsRS485/RS232/GPRS<br /> Working Temp-20℃~+60℃<br /> Purge Gas 0.3MPa ~ 0.8MPa N2, clean air<br /> Power supply24VDC, <20W<br /> CertificatesATEX, IECEx, CE<br /> Application Of LGT-100 Cross Stack & In-Situ Laser Gas Analyzer<br /> Apply to converter gas recovery gas analysis, CDQ circulating gas analysis; oxygen measuring electric fishing coke oven gas after analysis; pulverized coal injection gas analysis; ammonia escaping gas analysis in the cement industry; trace CO detection and analysis electricity, cement, environmental protection; HCl and HF trace analysis in environmental protection and chemical industry.</p> <p><a href="https://www.zetian-group.com/uploads/image/20190516/11/lgt-100-cross-stack--in-situ-laser-gas-analyzer.png" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190516/11/lgt-100-cross-stack--in-situ-laser-gas-analyzer.png" alt="lgt-100-cross-stack--in-situ-laser-gas-analyzer.png" /></a><br /> <a href="https://www.zetian-group.com/uploads/image/20190516/11/lgt-100-cross-stack--in-situ-laser-gas-analyzer-details-1.png" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190516/11/lgt-100-cross-stack--in-situ-laser-gas-analyzer-details-1.png" alt="lgt-100-cross-stack--in-situ-laser-gas-analyzer-details-1.png" /></a></p> 2020-11-09T11:03:14+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/qlhP6v9mzSf zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/qlhP6v9mzSf#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/qlhP6v9mzSf HM-200 Hygronom(2020年11月19日) <p><a href="http://www.folkd.com/detail/%2Fwww.zetian-group.com%2Fproducts%2Fhm-200-hygronom">http://www.folkd.com/detail//www.zetian-group.com/products/hm-200-hygronom</a></p> <p>Overview<br /> Hygronom is used to measure the humidity of flue gas emitted by pollution sources. According to measured humidity, it converts wet gas concentration into dry gas concentration. In addition, it also can be used in industrial online humidity monitoring.<br /> HM-200 hygronom (humidity meter online) is an intelligent humidity/ oxygen transmitter, which employs microprocessor as the core, and frequency conversion icon oxygen sensor as a measuring unit. The installation method adopts a heat tracing pipeline installation. It is a self-developed product, of which, the core component is from Switzerland.</p> <p>Under the effect of the air pump, the flue gas inside the stack enters the measurement module after heating from the heat tracing probe. The whole process of extraction, measurement, and discharge is with heat tracing to prevent gas from condensation, which will affect the measurement of moisture in the flue gas. The flue gas enters the measurement module after heating and the frequency conversion icon oxygen sensor will start to measure gas concentration. After the measurement, the gas can get into an analyzer for the measurement of other components.<br /> Features Of HM-200 Hygronom<br /> Portable structure, easy to install and disassemble<br /> Able to measure the humidity of 300℃ flue gas<br /> Able to match with the large-scale system for measurement or independent measurement<br /> The probe is equipped with heat tracing function to prevent condensate water from damaging probe and affecting measuring value<br /> Imported core components with high-performance index and reliability<br /> Technical Parameter Of HM-200 Hygronom<br /> Measurement rangeO2: 0~25.00%, H2O: 0~40.00% (volume ratio )<br /> SensorFrequency conversion icon oxygen sensor (2)<br /> Accuracy0~1%   O2:±1.5%F.S.<br /> 0~25%  O2:±1.5% of measured value<br /> 0~40.00%  H2O:±1%F.S.<br /> Stability0~1%   O2:±1.5%F.S./7d<br /> 0~25%  O2:±1.5%/7d of measured value<br /> 0~40.00%  H2O:±1%F.S./7d<br /> Response timeT90<30s<br /> Sensor life>2 years (under normal use)<br /> Transmitter life>5 years (under normal use)<br /> Power supply24VDC<br /> Instrument weightNet weight about 2.25kg  (include operation panel)<br /> Ambient temperatureTransmitter: -10°C~+50°C<br /> Probe: 0~300℃  (except probe cable)<br /> Ambient humidity<85%RH<br /> Power consumptionMaximum about 35VA (heating)<br /> Under normal working: 30~31W<br /> Sample gas flow(2~6)L/min<br /> Analog output (2 sets)Settable 4-20mA, 0-20mA, 0-1-5-10V, 1-5V<br /> CommunicationRs485 (standard)/RS232 (optional)<br /> Application Of HM-200 Hygronom<br /> It can be widely applied in high-temperature (300℃) gas (such as desulfuration and denitration) humidity measurement of Continuous Emission Monitoring System (CEMS), humidity measurement and control in fields including wood, building material, papermaking, chemical industry, fiber, pharmacy, textile, tobacco, vegetable and food processing.</p> <p><a href="https://www.zetian-group.com/uploads/image/20190516/13/hm-200-moisture-analysis-module.png" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190516/13/hm-200-moisture-analysis-module.png" alt="hm-200-moisture-analysis-module.png" /></a></p> 2020-11-09T11:02:44+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/HUxmAo7btH5 zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/HUxmAo7btH5#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/HUxmAo7btH5 HM-100 High-temperature Hygronom(2020年11月18日) <p><a href="http://sco.lt/6SvXKy">http://sco.lt/6SvXKy</a></p> <p>Overview<br /> Hygronom is also called gas moisture meter or dew-point meter, which is used to measure the humidity of flue gas emitted by pollution source. According to measured humidity, it converts wet gas concentration into dry gas concentration. In addition, it also can be used in industrial online humidity monitoring.<br /> HM-100 flue gas hygronom (high temperature gas analyzer) is equipped with an internal high-precision capacitance digital temperature & humidity sensor. The installation method adopts the in-situ immersion installation. It is a self-developed product, of which, the core component is from Switzerland. Put the sensor inside stack to get in touch with flue gas. The probe needs preheating to prevent gas from condensation, which will affect the measurement of moisture in the flue gas. After gas contacts with the measurement chip, the chip will change capacitance to measure flue gas concentration.<br /> Features Of HM-100 High-temperature Hygronom<br /> • The product is convenient for installation, disassembly, and cleaning with small and compact structure<br /> • Direct and simple key operation on site<br /> • The probe is equipped with heat tracing function to prevent condensate water from damaging humicap and thermal resistance<br /> • Imported core components with high-performance index and reliability<br /> Technical Parameter Of HM-100 High-temperature Hygronom<br /> Measurement RangeH2O: 0~40.00%(volume percent)(optional)<br /> Humidity sensorResistance-capacitance<br /> Temp sensorPt100 platinum resistor<br /> Accuracy0~40.00% H2O:±2%<br /> Repeatability0~40.00% H2O:±1%<br /> Stability0~40.00% H2O:±1%F.S./7d<br /> Response timeT90<6s<br /> Sensor life>2 years (under normal use)<br /> Transmitter life>5 years (under normal use)<br /> Power supply220VAC<br /> Instrument weightAbout 10kg<br /> Power consumptionMaximum about 35VA (heating)<br /> Ambient temperatureTransmitter: -10°C~+55°C<br /> Probe: 0~180°C (except probe cable)<br /> Ambient humidity<95%RH<br /> Sample gas flow(2~6)L/min<br /> Analog output (2 sets)Temperature and humidity, 4-20mA<br /> CommunicationRs232 (standard)<br /> Typical Application Of HM-100 High-temperature Hygronom<br /> 1.High-temperature humidity measurement in exhaust emission (CEMS) of fire coal and oil burning boiler<br /> 2.Humidity measurement in food processing<br /> 3.Humidity measurement in wood, building material, and papermaking industry<br /> 4.Humidity measurement in fields of chemical industry and fiber<br /> 5.Humidity measurement under high temperature of open width dyeing in dyeing & printing industry</p> <p><a href="https://www.zetian-group.com/uploads/image/20190516/13/hm-100-humidity-analyzer.png" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190516/13/hm-100-humidity-analyzer.png" alt="hm-100-humidity-analyzer.png" /></a></p> 2020-11-09T11:02:11+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/jAEk3LSVuGk zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/jAEk3LSVuGk#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/jAEk3LSVuGk Gas Analyzers(2020年11月17日) <p><a href="http://sco.lt/5nLImW">http://sco.lt/5nLImW</a></p> <p>With high accuracy and reliability, low operating costs, fast response time, wide measurement range and application fields, this laser gas analyzer equipment has reached or even exceeded the level of similar products at home and abroad.<br /> The gas monitoring instruments are tools for gas leakage concentration detection. It mainly uses gas sensors to detect the types of gases present in the environment.<br /> All sensors used to detect gas composition and concentration are called gas analysis equipment, regardless of whether it uses physical methods or chemical methods. For example, sensors that detect gas flow are not considered gas sensors, but thermal conductivity gas analyzers are important gas sensors, although they sometimes use generally the same detection principles.<br /> TDLAS (Tunable Diode Laser Absorption Spectroscopy) mainly uses the character that tunable laser's narrowband and wavelength change with the current. So by precisely modulating the current of tunable laser, it can scan a certain absorption peak of detected gas (no absorption of background gas). And after obtaining the second harmonics absorbed by detected gas, it finally works out the concentration of detected gas by using this second harmonics and line-width.<br /> ZETIAN, a gas analyser manufacturer, offers high-quality multi gas analyzers such as LGT series. By using a tunable semiconductor laser, LGT series laser gas analyzer scans the specific absorption lines of the measured gas (no background gas) to get the second harmonic of the gas. Through processing and analyzing the second harmonic and the broadening information of the gas, the concentration of the gas is obtained.</p> <p>Continuous gas analyzers are widely used in petrochemical, chemical, coal, electricity, automobiles, air purification, building HVAC, medicine, food, environmental protection, telecommunications, home appliances, metallurgy, municipal gas, environmental monitoring and many other fields. It can also perform gas concentration detection or leak detection on tunnels, pipelines, tanks, enclosed spaces, etc., to meet the measurement needs of special occasions.</p> <p><a href="https://www.zetian-group.com/uploads/image/20190516/11/lgt-200-flameproof-laser-gas-analyzer.png" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190516/11/lgt-200-flameproof-laser-gas-analyzer.png" alt="lgt-200-flameproof-laser-gas-analyzer.png" /></a><br /> <a href="https://www.zetian-group.com/uploads/image/20200914/15/lgt-300-one-side-installation-laser-gas-analyzer.jpg" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20200914/15/lgt-300-one-side-installation-laser-gas-analyzer.jpg" alt="lgt-300-one-side-installation-laser-gas-analyzer.jpg" /></a><br /> <a href="https://www.zetian-group.com/uploads/image/20190523/09/em-5-flue-gas-analyzer-1.jpg" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190523/09/em-5-flue-gas-analyzer-1.jpg" alt="em-5-flue-gas-analyzer-1.jpg" /></a></p> 2020-11-09T11:01:38+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/pk3LtbfVTLP zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/pk3LtbfVTLP#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/pk3LtbfVTLP FT-2000P Portable FTIR Gas Analyzer(2020年11月16日) <p><a href="http://sco.lt/7ucmRM">http://sco.lt/7ucmRM</a></p> <p>Overview of Portable Ftir Analyzer<br /> Based on FTIR technology, FT-2000P portable FTIR gas analyzer can continuously monitor various kinds of components in the emission, such as SO2, NOx (NO, NO2), CH4, NH3, HCl, HF, CO, CO2, O2, H2O. According to actual measuring need, it can be extended to measure other components, like SO3, N2O,etc. This portable system mainly comprises FTIR analyzer and sampling probe. It has features of high measurement accuracy, wide dynamic range and low detection limit.<br /> Feature Of FT-2000P Portable FTIR Gas Analyzer<br /> Warming up is no required for the analyzer to realize fast measurement;<br /> Applicable for high humidity and dust occasion;<br /> Optical length up to 13m, extremely low detection limit, high range dynamics, satisfy the monitoring of small emission limit;<br /> By applying OLS and PLS techniques and selecting, interference from H2O or others can be effectively eliminated;<br /> Quick site sampling, analysis and easy operation.<br /> Application Of FT-2000P Portable FTIR Gas Analyzer<br /> Apply to dust and noise online monitoring in construction sites, roads, residential, factory sector, tourism, waste incineration plants and other construction sites and production situations.<br /> Specification Of FT-2000P Portable FTIR Gas Analyzer<br /> principle:fourier transform infrared spectroscopy (FTIR)<br /> Range:SO2: (0~75) mg/m3<br /> NO: (0~200) mg/m3<br /> NO2: (0~40) mg/m3<br /> NOx: (0~200) mg/m3<br /> CO: (0~75) mg/m3<br /> H2O: (0~40) %<br /> CH4: (0~20) mg/m3<br /> NH3: (0~10) mg/m3<br /> HCl: (0~15) mg/m3<br /> HF: (0~10) mg/m3<br /> CO2: (0~20) mg/m3<br /> Pretreatment Method:condensation dewatering/whole process high temperature (optional)<br /> Repeatability:≤2%<br /> Zero Drift:≤±2%F.S./24h<br /> Span Drift:≤±2%F.S./24h<br /> Sampling Flow:(1.5±0.5) L/min<br /> Response Time:≤90s (T90)<br /> Enclosure Protection:IP41<br /> Working Temp.:0~45℃<br /> Working Pressure:80kPa~106kPa<br /> Humidity:0~95%RH<br /> Communication:RS232&USB<br /> <a href="https://www.zetian-group.com/uploads/image/20190708/19/ft-2000p-environmental-quality-monitoring-system.jpg" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190708/19/ft-2000p-environmental-quality-monitoring-system.jpg" alt="ft-2000p-environmental-quality-monitoring-system.jpg" /></a></p> 2020-11-09T11:01:04+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/imktKXNgb8S zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/imktKXNgb8S#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/imktKXNgb8S EM-5P Portable Flue Gas Analyzer(2020年11月15日) <p><a href="http://getpocket.com/redirect?&url=https%3A%2F%2Fwww.zetian-group.com%2Fproducts%2Fem-5p-portable-flue-gas-analyzer%2F&h=32798131e446fc657f91d9a58f13813e88524314a842eefb6c1bc7a389f335a7">http://getpocket.com/redirect?&url=https://www.zetian-group.com/products/em-5p-portable-flue-gas-analyzer/&h=32798131e446fc657f91d9a58f13813e88524314a842eefb6c1bc7a389f335a7</a><br /> <a href="http://sco.lt/6qLRZI">http://sco.lt/6qLRZI</a></p> <p>Overview<br /> EM-5P portable gas monitoring system mainly consists of gas monitoring sensors (SO2, NOx, CO, CO2), sample conditioning unit, sampling unit and heat tracing pipe. The main structural parts include gas sampler and pipeline, sample preconditioning unit and gas analyzer. It is equipped with android<br /> touch screen, having big data storage; with multi-port output; It also has a micro printer for real-time monitoring data.<br /> Feature Of EM-5P Portable Flue Gas Analyzer<br /> Low detection limit and temperature-drift;<br /> Getting NOx by directly measuring NO and NO2 which without NO2→NO converter;<br /> Not affected by the interference of background elements such as dust and H2O;<br /> No optical moving parts, high reliability, no interference to the measurement by field;<br /> Good portability and mobility.<br /> Application Of EM-5P Portable Flue Gas Analyzer<br /> Apply to multi-level environmental monitoring station, the third party inspection agencies, online analysis instrument production/sales/operations business who do the acceptance of environmental protection, emergency detection, instrument calibration, polluters audits to the industrial flue gas emissions occasions of coal-fired power plants, gas power plants, iron and steel plants, and laboratory gas test, etc.<br /> Specification Of EM-5P Portable Flue Gas Analyzer<br /> Analyzer mode:Normal Temperature-Condensation Water Removal/High Temperature-Full Temperature<br /> Principle:UV DOAS (SO2, NO), electrochemistry (O2), electrochemistry/TD-LAS (CO), infrared (CO2)<br /> Response Time:≤90s (T90)<br /> Warm-up Time:normal temperature 10 minutes/high temperature 40 minutes<br /> Power Supply:220VAC±22V, normal temperature 50W/high temperature 350W<br /> Range:0~50~1500mg/m3 (SO2/NO/NO2) , 0~25% (O2) , 0~500~10000ppm(CO) ,0~65% (CO2)<br /> Linearity Error:≤2%F.S.<br /> Zero Drift:≤±2%F.S./24h<br /> Span Drift:≤±2%F.S./24h<br /> Working Temp.:5℃~45℃<br /> Working Humidity:0~85%RH<br /> Dimension:498mm×182mm×236mm<br /> Weight:about 12kg</p> <p>Among all the online portable flue gas analyzer suppliers in China, ZETIAN is the only high and new technology company that has a full set of intellectual property rights of flue gas monitoring. Its independent research and development products include ultraviolet glue gas analyzer, dust monitor, temperature pressure flow, humidity meter, HCl analyzer, HF analyzer, pretreatment system, monitoring software, etc.</p> <p><a href="https://www.zetian-group.com/uploads/image/20190708/18/em-5pportablefluegasanalyzer.jpg" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190708/18/em-5pportablefluegasanalyzer.jpg" alt="em-5pportablefluegasanalyzer.jpg" /></a></p> 2020-11-09T11:00:34+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/RfoUvIr3F3T zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/RfoUvIr3F3T#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/RfoUvIr3F3T EM-5 Flue Gas Analyzer(2020年11月14日) <p><a href="http://sco.lt/8luy6y">http://sco.lt/8luy6y</a><br /> <a href="http://www.folkd.com/ref.php?go=https%3A%2F%2Fwww.zetian-group.com%2Fproducts%2Fem-5-flue-gas-analyzer">http://www.folkd.com/ref.php?go=https://www.zetian-group.com/products/em-5-flue-gas-analyzer</a></p> <p>Overview<br /> EM-5 series flue online gas analyzer is a series of self-developed gas analysis products for online gas analysis of domestic as well as foreign environmental protection and industrial control. Based on UV Differential Optical Absorption Spectroscopy (DOAS) technology and chemometrics algorithm (PLS), it is able to measure the gas concentration of SO2, NO, NO2, O2, NH3, Cl2, O3, H2S, Ch3 and etc.<br /> Features Of EM-5 Flue Online Gas Analyser<br /> High measurement accuracy<br /> Minimum detection limit of SO2, NO, NO2 can reach 1mg/m3 (15m optical path)<br /> Ultraviolet has no moisture absorption, undisturbed by moisture and dust<br /> No cross interference between measured gases (refer to table 1)<br /> Measure NO and NO2 simultaneously without converter<br /> Low detection limit<br /> Measuring gas<br /> InterferenceSO2NONO2O2<br /> SO2 (500ppm)/<1ppmnono<br /> NO (500ppm)no/nono<br /> NO2 (500ppm)no<1ppm/no<br /> H2O (no dew)nononono<br /> CO (1000ppm)nononono<br /> CO2 (20%)nononono<br /> O2 (21%)nonono/</p> <p>High reliability<br /> Small zero drift and span drift<br /> Modular design<br /> No optical moving parts, without vibration influence<br /> Strong gas chamber, low cost<br /> Automatic adjustment spectrum technology, long maintenance-free period<br /> Adopt pulse light source with 10-year service life<br /> Technical Parameter Of EM-5 Flue Gas Analyzer<br /> Measurement PrincipleUV-DOAS+PLS<br /> VersionsRegular rangeLow rangeUltra-low range<br /> RangesMin rangeMax rangeMin rangeMax rangeMin rangeMax range<br /> ComponentSO20-300ppm0-3000ppm0-100ppm0-300ppm0-50ppm0-100ppm<br /> NO0-300ppm0-3000ppm0-100ppm0-300ppm0-50ppm0-100ppm<br /> NO20-500ppm0-4000pp0-300ppm0-1000ppm0-100ppm0-200ppm<br /> O2 (ECD or ZrO2)0-5%0-25%0-5%0-25%0-5%0-25%<br /> Linearity≤±3%F.S.<br /> Repeatability≤2%<br /> Zero Drift≤±2%F.S./7d<br /> Span Drift≤±2%F.S./7d<br /> Response Time(T90)≤50s<br /> Working Temperature-20℃~+50℃<br /> Preheating TimeNo preheating20min40min<br /> Sample Gas InterfaceΦ6 Bi-Lok<br /> Sample Gas FlowRange: (0.5~2)L/min, fluctuation<25%<br /> Sample Gas PressureCurrent ambient pressure ±0.1Bar<br /> Sample Gas Temp.0℃~+50℃<br /> Sample Gas HumidityNo condensation (under sample gas temperature)<br /> 4-20mA Input3 , configurable, 100Ω load<br /> 4-20mA Output5, output content can be configured, maximum load capacity ≤800Ω<br /> Switching value Input6 , configurable<br /> Relay Output14, output content can be configured. DC30V2A<br /> Digital I/O1×Rs232, 1×Rs485 (Support Modbus protocol)<br /> Installation Method19’ panel<br /> Supply Voltage220VAC±10%<br /> Rated PowerAbout 100WAbout 120W</p> <p>Application Of EM-5 Flue Gas Analyzer<br /> Coal-fired power plant<br /> Cement plant<br /> Industrial furnace<br /> DeSOX process monitoring<br /> DeNOX process monitoring<br /> Waste incineration plant<br /> PVC process in chlor-alkali plant<br /> Titanium dioxide production process<br /> Sulfur recovery process<br /> Natural gas purification process<br /> Methyl iodide analysis for the coal chemical industry<br /> On-line air monitoring<br /> With features of high measurement accuracy, high reliability, fast response time, wide application scope, it can be widely applied in occasions of environment online monitoring, industrial process control, safety monitoring and etc.<br /> Depended on years of flue gas analyzer research experience and combined with practical experience of thousands of successful application cases, the analyzer has derived multiple types (standard type, low emission type, ultra-low emission type, and customized type) to meet different index requirements in different working condition.<br /> UV DOAS technology. The optical technology platform consists of a light source, gas chamber, optical fiber and spectrograph (including the diaphragm, a holographic grating, linear array detector) and other optical components.<br /> Ultraviolet light emitted by light source enters the gas chamber by an optical window and absorbed by measured sample gas flowed through the gas chamber. The light carrying sample absorption information will be gathered by the lens and coupled into an optical fiber and then transmits into spectrometer through fiber. After light splitting and photo-voltaic conversion, the gas absorption spectrum is obtained.<br /> The corresponding component concentration in the gas can be calculated by analyzing the spectrum.<br /> Note: the difference among standard analyzer, low emission analyzer, and ultra-low analyzer is the different optical path length of gas chamber; for standard analyzer, it adopts dual lens collimation system with 0.25m optical path; for low emission analyzer, it adopts multiple return structure with 1m optical path; for ultra-low emission analyzer, it uses white cell structure.<br /> Zetian Group has high-quality continuous flue gas analyzer for sale, contact us now.<br /> <a href="https://www.zetian-group.com/uploads/image/20190523/09/em-5-flue-gas-analyzer-1.jpg" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190523/09/em-5-flue-gas-analyzer-1.jpg" alt="em-5-flue-gas-analyzer-1.jpg" /></a></p> 2020-11-09T10:59:46+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/gNgXgtAP9JZ zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/gNgXgtAP9JZ#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/gNgXgtAP9JZ DPM-6000 PM Monitor PM2.5/PM10(2020年11月13日) <p><a href="http://sco.lt/7zsMLY">http://sco.lt/7zsMLY</a></p> <p>Overview<br /> Inhalable particle content is one of the most important indexes for measuring air quality. Combining years of experience in developing environment and safety monitoring instruments as well as the latest demand at home and abroad, our company has launched a new generation DPM-6000 atmospheric particulate monitor with high accuracy, reliability, stability and economy. It can measure PM10, PM2.5 and dust particles of other cut sizes, widely applied in inhalable particles concentration detection in environmental atmosphere monitoring.<br /> Principle Of DPM-6000 PM Monitor PM2.5/PM10<br /> The monitoring principle of the analyzer is mainly based on enrichment technology of atmospheric particulate and beta ray attenuation method. The instrument concentrates on particulate matters whose aerodynamic equivalent diameter is smaller than 2.5/10μm on the rolled filter membrane. The instrument adopts low-radiation 14C as a radioactive source. The emitted Beta-ray passes through the filter membrane with contaminants and will be received by the detector. The detector is composed of a photo-multiplier tube (or Geiger detector), plastic scintillator and counter. The thickness of enrichment can be analyzed quantificationally according to Beta-ray energy that detector received, then the PM2.5/10 concentration in the air can be calculated.<br /> Features Of DPM-6000 PM Monitor PM2.5/PM10<br /> The design of the gas path keeps filter paper, a radioactive source and detector immovable during enrichment and measurement, ensuring a good lower detection limit.<br /> US EPA standard beta ray attenuation method, which spares the complicated operations of TEOM, such as manually replace filter paper and weight. Compared to the light scattering method, it has higher measurement accuracy.<br /> Cutter, based on simulation verification of aerodynamics, will provide a various selection of accurate particle.<br /> Sizes: PM1, PM2.5, PM10, TSP.<br /> Sampling flow is measured by a mass flow sensor and corrected with collected ambient temperature and pressure to get the sampling flow of the field.<br /> Use C14 source which is of low-density, low activity, and long half-life to realize stable measurement. No special protection is needed. Reliable and safe.<br /> Flexible paper-pressing structure. Mechanical driving design is simple and reliable; greatly reduce paper breaking and paper jam and avoid the error caused by the moving of filter paper.<br /> The pipeline heating system is used to eliminate interference from ambient humidity and make the detector fit into sudden.<br /> Flow control system with precise closed-loop feedback; stable sampling flow and small error.<br /> Various external ports, such as RS232/RS485, 4~20mA and etc.<br /> Low maintenance frequency, once a year.<br /> Specification Of DPM-6000 PM Monitor PM2.5/PM10<br /> Measuring principleBeta ray attenuation method<br /> Performance IndexMeasuring Range0~1000μg/m3³or 0~10000μg/m3 (optional)<br /> Radioactive Source14C (carbon-14), radioactivity≤60μCi<br /> Accuracy≤5%<br /> Display Resolution1μg/m3<br /> Lower Detection Limit5μg/m3<br /> Flow Error≤±2% (generally set at 16.67L/min)<br /> Sampling Flow Stability≤±2% working point flow/24h<br /> Sampling Period≤1h (time is settable)<br /> Sampling FlowDefault 16.67L/min<br /> ParallelismPM10≤10%, PM2.5≤15%<br /> Filter Paper TapeFilter Paper TapeGlass fiber, inner diameter: 40 mm, width: 30 mm, service time 1 month (work period 1 h)<br /> Interface Para.I/ORs232, RS485, 4-20mA, GPRS (optional)<br /> Data StorageOne year<br /> Working ConditionCutting headerAmbient temperature (-40~50)℃,  ambient pressure (80~106kPa)<br /> DetectorAmbient temperature (5-40)℃, ambient pressure (80-106kPa),  humidity (≤90%)<br /> Power SupplyAC (220±22)V, (50±1)Hz<br /> Dimension & Weight483×407×322(mm) (L×W×H);  Monitor 30kg, Pump 8kg</p> <p>Application Of DPM-6000 PM Monitor PM2.5/PM10<br /> Inhalable particle real-time monitoring in industry,, construction, residential district and etc.<br /> Environment assessment, permission, and pollution forecast and pre-warning.<br /> Ambient air quality monitoring and mobile air monitoring experimental station.<br /> Occupational disease research, and long-term background environment research.<br /> Secondary emission monitoring (coal storage area, wharf, etc.).</p> <p><a href="https://www.zetian-group.com/uploads/image/20190516/10/dpm-6000-pm-monitor-pm2.5-pm10.png" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190516/10/dpm-6000-pm-monitor-pm2.5-pm10.png" alt="dpm-6000-pm-monitor-pm2.5-pm10.png" /></a></p> 2020-11-09T10:58:52+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/kSxBjS2EbF8 zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/kSxBjS2EbF8#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/kSxBjS2EbF8 Continuous Emission Monitoring System(2020年11月12日) <p><a href="http://sco.lt/6pD332">http://sco.lt/6pD332</a></p> <p>Among all the online continuous emission monitoring system suppliers in China, ZETIAN is the only high and new technology company that has a full set of intellectual property rights of flue gas monitoring. Its independent research and development products include ultraviolet glue gas analyzer, dust monitor, temperature pressure flow, humidity meter, HCl analyzer, HF analyzer, pretreatment system, monitoring software, etc.<br /> Continuous emissions monitoring system(CEMS) of ZETIAN Technology can monitor gases, including So2, NOx, O2, dust, humidity, temperature, pressure, flow parameters, etc. It can be widely used in all kinds of component continuous monitoring situation such as boilers, industrial furnaces, incinerator emissions, etc.<br /> In addition, it also can monitor gases for a particular occasion such as HCl, HF, CO, CO2, NH3, H2S, Cl, VOC, etc…<br /> Our online continuous emission monitoring system has four basic parts: the dust monitoring subsystem, gaseous pollutants monitoring subsystem, flue gas parameter monitoring subsystem, system control and data acquisition and processing subsystem. It can monitor SO2, NOx, O2, dust, temperature, pressure, flow rate and other parameters such as HCl, HF, CO, CO2 for specific occasions. After dedusting by sampling probe, tracing by heating pipe, dehydration and cooling by two-step condensing, the measured gas is analyzed by the heated gas analysis module (TDLAS and DOAS technique). It is an effective solution to solve the technical problem that large humidity variation of the waste incineration and other occasions lead to measuring data fluctuation.<br /> This system obeys continuous emission monitoring system working principles, and adopts difference optical absorption spectroscopy (DOAS) analysis technology to measure SO2 and NOx; electrochemical to measure O2. And temperature, pressure, flow rate are respectively measured by pressure sensors and pitot micro differential pressure method. Laser scattering method is adopted to monitor dust and high temperature capacitance for humidity. Besides of SO2 and NOx, DOAS technology can also analyzer gases NH3, Cl2, H2S, O3, etc. If system is extended with other analysis modules, it can also analyze and measure HF, HCl, CO, CO2 and so on at the same time.<br /> Features of Online Continuous Emission Monitoring System:<br /> The measure lower limit of ultraviolet flue gas analyzer is as low as 1 mg/m3, and fully qualified for technical parameters in ultra-low emission monitoring measurement occasions;<br /> The latest laser forward scattering dust monitor is suitable for high humidity flue gas, light-leaking stack and low dust emission and other application points;<br /> Integration of low flow velocity of temperature pressure flow product solves the problem that normal product has inaccuracy measurement under low flow velocity of flue gas;<br /> Laser HCl analyzer, HF analyzer have passed national explosion-proof certification, and have the wide recognition in the industry;<br /> The company uses UV difference gas absorption spectrum analysis technology which is fully independent intellectual property rights, effectively avoiding interference of dust and moisture on measurement;<br /> By combining multistage dust filtration technology and regular blowing back, it effectively prevents dust blocking filters and the pipeline, as well as polluting analyzer measurement pool. It can adapt to the worst environment of the high dust, high humidity, high temperature, high corrosion resistance, etc. ;<br /> Ultraviolet flue gas analyzer can simultaneously measure the parameters of SO2, NO, NO2 (Being independent of NO), O2, humidity, Nox can be obtained by direct measuring of NO and NO2, without the converter of NO2 to NO;<br /> Simple structure, without optical moving parts, long period free from maintenance, high resistance to vibration;<br /> Advanced UV difference spectrum technology, spectrum holographic grating spectrometer, diode array detection, to obtain a complete continuous absorption spectrum, long takanami resolution to ensure low detection limit, small temperature drift, fast response time;<br /> Analyzer gas chamber is processed with the features of strong gas chamber, low cost and low impact by water and dust. The detector and the gas chamber adopts optical fiber for connection. It is easy to replace and maintenance cost is low;<br /> Completely independent research and development of the core module and algorithm, the system has strong market competitiveness;<br /> The system structure is compact with high integration, easy to transport and install.</p> <p><a href="https://www.zetian-group.com/uploads/image/20190617/18/ga-5000dn-denox-ammonia-slip-online-monitoring-system.jpg" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190617/18/ga-5000dn-denox-ammonia-slip-online-monitoring-system.jpg" alt="ga-5000dn-denox-ammonia-slip-online-monitoring-system.jpg" /></a><br /> <a href="https://www.zetian-group.com/uploads/image/20190617/18/em-5-hw-continuous-emission-monitoring-system-hot-wet.jpg" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190617/18/em-5-hw-continuous-emission-monitoring-system-hot-wet.jpg" alt="em-5-hw-continuous-emission-monitoring-system-hot-wet.jpg" /></a><br /> <a href="https://www.zetian-group.com/uploads/image/20190708/20/em-5continuousemissionmonitoringsystemin-situ.png" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190708/20/em-5continuousemissionmonitoringsystemin-situ.png" alt="em-5continuousemissionmonitoringsystemin-situ.png" /></a></p> 2020-11-09T10:58:09+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/fqTWeB9QkSG zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/fqTWeB9QkSG#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/fqTWeB9QkSG Continuous Emission Monitoring & Process Control(2020年11月11日) <p><a href="http://www.folkd.com/detail/%2Fwww.zetian-group.com%2Fproducts%2Fcontinuous-emission-monitoring-process-control">http://www.folkd.com/detail//www.zetian-group.com/products/continuous-emission-monitoring-process-control</a><br /> <a href="http://sco.lt/7Du9Me">http://sco.lt/7Du9Me</a></p> <p>The instruments and analyzers produced by ZETIAN now are widely used at home and abroad. They are: UV DOAS gas analyzer, laser TDLAS gas analyzer, gas analysis module, forward/backward laser dust monitoring devices, hygroscope for high temperature, continuous emission monitoring system (CEMS Analyzer), denitration escape ammonia analyzer, sulphur analyzer, trace Cl analyzer system, immersive UV broad spectrum water analyzer, ammonia nitrogen analyzer, colorimetric heavy analyzer, anodic stripping voltammetry heavy metal analyzer etc.<br /> After years of developing, ZETIAN, as one of the most professional CEMS manufacturers, has cooperated with and attracted many worldwide clients of online monitoring and process control, including system integrator, agents, operation and maintenance providers, equipment manufacturers, thermal power plants, sewage treatment plants, chemical plants and the like.<br /> Working Principle of CEMS System (Particulate Matter)<br /> Features of the particle measurement subsystem:<br /> 1. Direct measurement without sampling system;<br /> 2. The probe does not touch the smoke;<br /> 3. Because standard materials are difficult to obtain, the factory usually calibrates with filters;<br /> 4. Dust and water vapor have a greater impact and are not suitable for measurement after wet purification facilities unless the flue gas is reheated to a temperature above the dew point of water<br /> 5. The back blowing air curtain needs 24 hours of operation (also when the furnace is stopped);<br /> 6. Changes in particulate composition and particle size affect the calibration of such analyzers;<br /> Particulate matter online performance requirements:<br /> Zero drift: ≤ ± 2% F.S.;<br /> Span drift: ≤ ± 2% F.S.;<br /> Correlation coefficient: ≥0.85 (when the upper limit of the measurement range ≤50mg / m³, ≥0.75)<br /> Working Principle of CEMS System (Gaseous Pollutants)<br /> Classification of online monitoring methods for gaseous pollutants:<br /> 1. Extractive continuous monitoring (dilute sampling method, direct sampling method)<br /> a. Dilute sampling method: collect flue gas and remove dust, and then use clean zero gas to dilute the dedusted flue gas according to a certain dilution ratio to reduce the concentration of gaseous pollutants, and introduce the diluted flue gas into the analysis unit for concentration analysis<br /> b. Direct extraction and sampling method (heating pipeline method): Insulate the dedusted flue gas through the heating pipe to keep the flue gas without dew condensation, send it to the drying device for dehumidification, and then send it to the analysis unit for concentration analysis.<br /> Features of dilution extraction system:<br /> 1. UV fluorescence measurement SO2, chemiluminescence measurement NOx;<br /> 2. Multiple analysis unit combinations are required;<br /> 3. The oxygen content needs to be equipped with a separate sampling system or a direct measurement method;<br /> 4. The measurement data needs to be converted into the dry flue gas value in the standard state;<br /> 5. The sample gas transmission does not use heating pipeline;<br /> 6. The air used for probe dilution needs to be strictly controlled;<br /> 7. Probe dilution ratio needs to be calibrated at any time;<br /> Features of the direct extraction system:<br /> 1. Infrared / ultraviolet light absorption measurement and analysis unit;<br /> 2. One analysis unit can measure SO2, NOx, CO2, CO at the same time;<br /> 3. The oxygen measurement (O2) unit and infrared unit can be placed in the same analyzer together;<br /> 4. The measured data is the dry flue gas value in the standard state, the data is intuitive;<br /> 5. Sample gas transmission adopts heating pipeline (above 120 ℃)<br /> 6. The pretreatment system is complex;<br /> 7. Requires good sealing;<br /> 2. On-site continuous monitoring<br /> What we can offer are high cost-effective intellectual monitoring instrumentation and analysis equipment, analysis module /component, CEMS program sets, complete set of water quality analysis program and other similar products. OEM and ODM are acceptable for us, and we can also provide operation, maintenance and other services.<br /> Continuous Emission Monitoring System (CEMS) consists of particulate matter monitoring subsystem, gaseous pollutants monitoring subsystem , flue gas parameters monitoring subsystem, system control and data acquisition and processing subsystem. It can monitor gases such as SO2, NOx, O2, dust, temperature, pressure, flow rate, humidity, etc. It can also be extended for a specific occasion to monitor HCl, HF, CO, CO2, NH3, H2S, Cl2, VOC and other parameters. The measured gas passes through sampling probe for dedusting, heating tube for sampling, then goes into the gas analysis module violet differential optical absorption spectroscopy (DOAS) for analysis measurements. It effectively solves the technical problems of dust and moisture interference on measurement, particularly in the case of low concentration measurements with an unparalleled advantage.<br /> It applies to the emission monitoring and process analysis of coal-fired power plant, garbage power plant, cement, glass, lime factory, ceramics factory, sinter, coke oven, the process of desulfurization and denitration technology.</p> <p><a href="https://www.zetian-group.com/uploads/image/20190523/09/hm-100-humidity-analyzer.jpg" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190523/09/hm-100-humidity-analyzer.jpg" alt="hm-100-humidity-analyzer.jpg" /></a><br /> <a href="https://www.zetian-group.com/uploads/image/20190523/10/dms200-dust-monitor-9.png" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190523/10/dms200-dust-monitor-9.png" alt="dms200-dust-monitor-9.png" /></a><br /> <a href="https://www.zetian-group.com/uploads/image/20190523/10/lgt-106-by-pass-laser-gas-analyzer.jpg" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190523/10/lgt-106-by-pass-laser-gas-analyzer.jpg" alt="lgt-106-by-pass-laser-gas-analyzer.jpg" /></a></p> 2020-11-09T10:57:39+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/cPsf49fQdlT zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/cPsf49fQdlT#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/cPsf49fQdlT Overview(2020年11月10日) <p><a href="http://sco.lt/76Eyqu">http://sco.lt/76Eyqu</a></p> <p>AM-5100 SO2 analyzer adopts ultraviolet fluorescence technique and combines advanced micro processing technology, which could provide accurate and reliable SO2 detection at low level ppb~ppm.This analyzer can be applied to atmospheric monitoring and dilution-based CEMS system.<br /> Features Of AM-5100 SO2 Analyzer<br /> Measurement range 0~500ppb to 0~20ppm, user selectable;<br /> High efficiency hydrocarbon remover and unique optical design, strong anti-interference ability;<br /> Dark current compensation at fixed time, high stability;<br /> Self checking function of light intensity attenuation;<br /> Adaptive signal filtering technology to optimize response time;<br /> Large capacity memory, automatic storage of historical data.<br /> Application Of AM-5100 SO2 Analyzer<br /> Atmospheric monitoring<br /> Specification Of AM-5100 SO2 Analyzer<br /> Range:0~500ppb, wide range 0~20,000ppb (optional)<br /> Unit:ppb, ppm, ug/m3, mg/m3<br /> Zero Point Noise:<0.2ppb (RMS)<br /> Low Detection Limit:0.4ppb<br /> Zero Drift:<1ppb/24h<br /> Span Drift:<5ppb/24h<br /> Response Time:<120s (T90)<br /> Linearity:<1%/F.S.<br /> Repeatability:<1%<br /> Sampling Flow Range:800SCCM±10%<br /> Ambient Temp.:5℃~40℃<br /> Dimension:178mm×430mm×635mm<br /> Weight:<15kg, external pump 5kg<br /> Power:200V~240V, 50/60Hz, 400W<br /> Analog Output:10V, 5V, 1V, 0.1V (optional)<br /> Comm.:RS232, RS485</p> <p><a href="https://www.zetian-group.com/uploads/image/20190708/19/am-5100so2analyzer.jpg" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190708/19/am-5100so2analyzer.jpg" alt="am-5100so2analyzer.jpg" /></a></p> 2020-11-09T10:57:02+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/eNOuR6Hvxg6 zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/eNOuR6Hvxg6#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/eNOuR6Hvxg6 Air Quality Monitor(2020年11月09日) <p><a href="http://sco.lt/8fbOT2">http://sco.lt/8fbOT2</a></p> <p>Air quality continuous online automatic monitoring system real-time monitor concentration changes of SO2, NOx, O3, CO, particulate matter (PM2.5, PM10) and other conventional pollution factor. It can be integrated with aerosols, VOCs, NH3, and halite (HF/HCl) according to customer's needs.<br /> Combined with the five-parameter analyzer (temperature, humidity, wind direction, wind speed and air pressure), the regional environment can be continuously measured in 24 hours. And then through the process of data collection, storage and analysis to achieve regional environmental air quality assessment. Monitoring system mainly consists of sampling system, analytical instruments, calibration systems, and data acquisition system four parts.<br /> Instrument features of air analyzer equipment:<br /> Support real-time display of data and data curve.<br /> Support historical data and historical alarm information query.<br /> Support for automatic calibration, remote operation and data network transmission.<br /> With the function of data management, information release, remote control, network management, system maintenance and so on.<br /> With various data analysis means, alarm data can be aggregated for statistical analysis, automatic reporting.<br /> The atmosphere is the basic condition for our survival. Air pollution has become a serious problem that affects human health and threatens human survival because of the persistent pollution and destruction of human activities.<br /> Air pollution control a complex system engineering which requires sub-regional and phased management. We need accurately assess regional air quality and continuously strengthen environmental governance since air quality online monitoring is of great significance. Air pollution analyzer suppliers like ZETIAN help to find solutions for you.<br /> The gaseous pollutant analyzer includes SO2 analyzer, NOx analyzer (chemiluminescence method), O3 analyzer, CO analyzer, VOCs analyzer, laser gas (HCl, HF, NH3, etc.) analyzer, NO2, analyzer(CAPS principle). While the particle analyzer consists of a PM2.5 analyzer, a PM10 analyzer and a matting instrument (aerosol analyzer).</p> <p><a href="https://www.zetian-group.com/uploads/image/20190527/14/dpm-6000-pm-monitor-pm2.5-pm10.png" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190527/14/dpm-6000-pm-monitor-pm2.5-pm10.png" alt="dpm-6000-pm-monitor-pm2.5-pm10.png" /></a><br /> <a href="https://www.zetian-group.com/uploads/image/20190708/16/eqms-vocs-online-monitoring-system.jpg" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190708/16/eqms-vocs-online-monitoring-system.jpg" alt="eqms-vocs-online-monitoring-system.jpg" /></a><br /> <a href="https://www.zetian-group.com/uploads/image/20190708/17/vehicle-exhaust-remote-sensing-system.png" rel="nofollow"><img src="https://www.zetian-group.com/uploads/image/20190708/17/vehicle-exhaust-remote-sensing-system.png" alt="vehicle-exhaust-remote-sensing-system.png" /></a></p> 2020-11-09T10:56:29+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/9i7O0Q3POSK zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/9i7O0Q3POSK#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/9i7O0Q3POSK WDet-5000UVI Immersion UV Water Analyzer(2020年02月19日) <p><a href="http://www.zetian-group.com/products/wdet-5000uvi-immersion-uv-water-analyzer/">http://www.zetian-group.com/products/wdet-5000uvi-immersion-uv-water-analyzer/</a></p> <p>Overview<br /> WDet-5000UVI is the first full-spectrum (200-800nm) immersion UV water analyzer at home. With features of the delicate and convenient structure, plug and play, auto cleaning function, it can be widely applied to measure indexes including COD, BOD, and turbidity in surface water, underground water, and municipal sewage.</p> <p>Technical Principle Of WDet-5000UVI Immersion UV Water Analyzer</p> <p>The analyzer adopts a pulse xenon lamp as the light source and ultraviolet spectrometer as a detector, which can collect the absorption spectrum of water pollution between 200nm and 800nm in real time. The water pollutant content can be analyzed in real time through the chemometrics algorithm technology. The optical path is shown as the following figure.</p> <p>The spectral probe can record a complete spectrum between 200nm to 800nm (UV-visible light) and distinguish the spectrum into 256 wavelengths to obtain "Spectral fingerprint". It can monitor multiple parameters simultaneously through the information contained in spectral fingerprint and compensate those parameters aiming at possible cross-sensitivity. The relevance between measuring result and laboratory result achieves high quality that simple optical instrument can never obtain before.</p> <p>Features Of WDet-5000UVI Immersion UV Water Analyzer</p> <p>Adopt a full spectrum (200-800nm) (UV-visible light) measurement technology and chemometrics algorithm. Compared with dual wavelength background deduction technology, it can measure more parameters and be less affected by composition change of sewage.<br /> Use high-pressure gas to clean probe automatically, or employ immersion electrical brush to clean.<br /> Not required for reagent preparation; save operating cost and no secondary pollution.<br /> Fast response time(about 2s), applied to occasions with high requirements for real-time.<br /> Without interference by chloride.</p> <p>Technical Specification Of WDet-5000UVI Immersion UV Water Analyzer</p> <p>Measuring MethodUV/visible light DOAS, wavelength range: 200-800nm<br /> Power supply12VDC<br /> Linearity2%F.S.<br /> Zero drift<1%F.S.<br /> Range (COD)0~50~200mg/L, larger range is customizable<br /> Measurement intervalMinimum 60s, period can be set<br /> Probe immersion depth<10m<br /> Optical pathAdjust according to actual working condition<br /> Water temp requirement5 ℃ ~ 45 ℃<br /> Probe IP gradeIP68<br /> Cleaning methodGas purging or immersion electric brush<br /> Auto cleaning periodExternal control<br /> External interfaceRS232, MODBUS protocol<br /> Probe dimensionΦ60mm×380.5mm<br /> Probe weight< 3kg<br /> Auto compensation of cross sensitivityTurbidity/organicsubstance<br /> Measuring range of Integrated temp-10 ℃ ~ 50 ℃<br /> Temperature sensor resolution0.1 ℃</p> <p>Hangzhou Zetian Technology is committed to the integrity, strength and quality of our water quality testing products. We're internationally recognized. Welcome you to visit us.</p> <p><a href="http://www.zetian-group.com/uploads/image/20190516/13/uv-water-quality-monitoring-analyzer_1557985441.png" rel="nofollow"><img src="http://www.zetian-group.com/uploads/image/20190516/13/uv-water-quality-monitoring-analyzer_1557985441.png" alt="uv-water-quality-monitoring-analyzer_1557985441.png" /></a><br /> <a href="http://www.zetian-group.com/uploads/image/20190516/13/uv-water-quality-monitoring-analyzer-installation.png" rel="nofollow"><img src="http://www.zetian-group.com/uploads/image/20190516/13/uv-water-quality-monitoring-analyzer-installation.png" alt="uv-water-quality-monitoring-analyzer-installation.png" /></a></p> 2020-02-10T17:34:17+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/UDBaNVxZCKy zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/UDBaNVxZCKy#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/UDBaNVxZCKy Water Quality Analyzers(2020年02月18日) <p><a href="http://www.zetian-group.com/products/water-quality-analyzers/">http://www.zetian-group.com/products/water-quality-analyzers/</a></p> <p>Hangzhou Zetian Technology Co., Ltd. is the only domestic company with five analysis technical platforms which are LED colorimetric platform, full spectrum colorimetric platform, cold atomic absorption colorimetric platform, anodic dissolution platform and electrode method platform. These five kinds of analysis platform can measure the common pollution factors in water, including COD, ammonia nitrogen, total phosphorus, total nitrogen and heavy metals such as copper, chromium, lead, zinc, mercury, arsenic, etc. At the same time, using the full spectrum colorimetric platform or anodic dissolution platform also can realize COD/ ammonia nitrogen integrated system, total phosphorus/ total nitrogen integrated system, and all kinds of heavy metal integrated system, etc.</p> <p>The water quality analyzer of Hangzhou Zetian Technology Co., Ltd. has been experienced years of on-site validation, stable and reliable, low failure rate. Product details are listed below.</p> <p>Peristaltic Pump Tube:<br /> The United States imported special rubber hose, long service life, a tube can use more than one year.</p> <p>Sample Module:<br /> Homemade sampling module uses the high pure PTFE material, disassembly easy to clean or replace, reliable operation, every channel is completely isolated.</p> <p>Control System:<br /> (1)Control solenoid valve uses non-contact electronic switch, no mechanical life.<br /> (2) Homemade control unit, after years of verification, low fault rate, high reliability, modular design, low maintenance cost.</p> <p>Instrument Protection-Grounding Design:<br /> Instruments have high-level intelligence, such as reagents fault adding warning (especially H2SO4 used in COD, if it is not H2SO4, it is likely to lead digestion tube burst), leakage protection (if there is leakage, the instrument will report errors), pressure relief valve (making pressure in digestion tube within a certain range).</p> <p>All the external interface and main circuit of equipment is in isolation, which makes the normal sample without the outside interference. Especially for unequal potential connection, its effect is particularly evident.</p> <p>In analog circuits (measurement module) also made electrical isolation, which makes the minimum possible interference on measurement.</p> <p>Measuring Parts:<br /> Modulating optical measurement makes no influence of external light on measurement, it is more stable.</p> <p>External Interface:<br /> Largest configuration has 2×4-20 mA output, 4×4-20 mA input, 2 switch input, 2 switch output, can access the PH meter, flow meter, ss and other equipment, and can display on the main interface.</p> <p>Technology Platform:<br /> It has five measuring platforms, suitable for the needs of different applications.</p> <p>Hangzhou Zetian Technology is committed to the integrity, strength and quality of our air quality monitor. We're internationally recognized. Welcome you to visit us.</p> <p><a href="http://www.zetian-group.com/uploads/image/20190708/19/wdet-7000-integration-water-quality-online-analyzer.jpg" rel="nofollow"><img src="http://www.zetian-group.com/uploads/image/20190708/19/wdet-7000-integration-water-quality-online-analyzer.jpg" alt="wdet-7000-integration-water-quality-online-analyzer.jpg" /></a><br /> <a href="http://www.zetian-group.com/uploads/image/20190708/19/wdet-5000cn-cyanide-online-analyzer.jpg" rel="nofollow"><img src="http://www.zetian-group.com/uploads/image/20190708/19/wdet-5000cn-cyanide-online-analyzer.jpg" alt="wdet-5000cn-cyanide-online-analyzer.jpg" /></a><br /> <a href="http://www.zetian-group.com/uploads/image/20190516/13/uv-water-quality-monitoring-analyzer.png" rel="nofollow"><img src="http://www.zetian-group.com/uploads/image/20190516/13/uv-water-quality-monitoring-analyzer.png" alt="uv-water-quality-monitoring-analyzer.png" /></a></p> 2020-02-10T17:33:37+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/QaQ5VmGEvHk zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/QaQ5VmGEvHk#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/QaQ5VmGEvHk DMS-100/MS-1000 Dust Monitor(2020年02月16日) <p><a href="http://www.zetian-group.com/products/ms-1000-dust-monitor/">http://www.zetian-group.com/products/ms-1000-dust-monitor/</a></p> <p>Overview<br /> DMS-100/MS-1000 is a self-developed online dust particle measuring device, adopting laser backward scattering measuring technology with imported core components. It is mainly used for continuous monitoring of PM emission concentrations of various pollution sources. It can be not only matched with CEMS but also be used separately or together with multiple dust monitors to form a dust monitoring network, sharing the same data collection and processing background.</p> <p>The product is widely applied in enterprises including thermal power, ferrous metallurgy, petrochemical industry, cement production, potting, waste incineration; flue gas emission monitoring in all kinds of power generating boiler, industrial kiln, and industrial boiler; monitoring and control in gas desulphurization and dust removal process.</p> <p>Principle Of DMS-100/MS-1000 Dust Monitor</p> <p>DMS-100/MS-1000 dust monitor consists of the optical part, circuit and signal processing part, calibrator and air curtain protection part.</p> <p>The laser beam (650nm) emitted by semiconductor laser enters the stack and produces scattering light by interaction with dust particles. The backscattered light enters the photosensitive detector through the convergence of the lens. The signal processing circuit converts the light signal into a standard signal in proportion to dust concentration and output, thus dust particle emission concentration of pollution source is obtained.</p> <p>Features Of DMS-100/MS-1000 Dust Monitor</p> <p>•Support online zero and span calibration<br /> •Automatic gain control function and temperature compensation<br /> •Convenient for installation, disassembly and cleaning with small and compact structure<br /> •Able to eliminate the influence of background stray light<br /> Specification Of DMS-100/MS-1000 Dust Monitor</p> <p>Measuring principleLaser backward scattering<br /> Measuring range0 ~ 200mg / m3, 0 ~ 10g / m3 (customizable)<br /> Indication error≤ ± 20%<br /> Indication repeatability10%<br /> Laser device650nm<br /> Medium temperature< 300 ℃<br /> Ambient Temperature-20 ~ + 45 ℃<br /> Stack diameter≥0.5m<br /> Analog output4-20mA, maximum load 800Ω<br /> COMM interfaceRs485, 2 ×relay output, bluetooth<br /> HMIIPC, APP(for MS-1000)<br /> Weight4kg<br /> Power< 3W<br /> Dimension158mm* 158mm*234mm (square)<br /> 158mm* 158mm*273mm (circular)<br /> Supply voltage24VDC ± 10%</p> <p>Installation Of DMS-100/MS-1000 Dust Monitor</p> <p>1. The instrument is installed on the stack by flange<br /> 2. The rain cover will be installed at the back end of the monitor<br /> 3. Power and gas source is connected at the back end of the monitor</p> <p>Hangzhou Zetian Technology is committed to the integrity, strength and quality of our water quality testing products. We're internationally recognized. Welcome you to visit us.</p> <p><a href="http://www.zetian-group.com/uploads/image/20190516/11/dms-100-ms-1000-dust-monitor_1557976417.png" rel="nofollow"><img src="http://www.zetian-group.com/uploads/image/20190516/11/dms-100-ms-1000-dust-monitor_1557976417.png" alt="dms-100-ms-1000-dust-monitor_1557976417.png" /></a><br /> <a href="http://www.zetian-group.com/uploads/image/20190516/11/dms-100-ms-1000-dust-monitor-2.png" rel="nofollow"><img src="http://www.zetian-group.com/uploads/image/20190516/11/dms-100-ms-1000-dust-monitor-2.png" alt="dms-100-ms-1000-dust-monitor-2.png" /></a></p> 2020-02-10T17:32:49+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/kV2DGhAKa7Z zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/kV2DGhAKa7Z#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/kV2DGhAKa7Z HM-200 Hygronom(2020年02月17日) <p><a href="http://www.zetian-group.com/products/hm-200-hygronom/">http://www.zetian-group.com/products/hm-200-hygronom/</a></p> <p>Overview<br /> Hygronom is used to measure the humidity of flue gas emitted by pollution sources. According to measured humidity, it converts wet gas concentration into dry gas concentration. In addition, it also can be used in industrial online humidity monitoring.</p> <p>HM-200 hygronom is an intelligent precision humidity meter, which employs microprocessor as the core, and frequency conversion icon oxygen sensor as a measuring unit. The installation method adopts a heat tracing pipeline installation. It is a self-developed product, of which, the core component is from Switzerland.</p> <p>Under the effect of the air pump, the flue gas inside the stack enters the measurement module after heating from the heat tracing probe. The whole process of extraction, measurement, and discharge is with heat tracing to prevent gas from condensation, which will affect the measurement of moisture in the flue gas. The flue gas enters the measurement module after heating and the frequency conversion icon oxygen sensor will start to measure gas concentration. After the measurement, the gas can get into an analyzer for the measurement of other components.</p> <p>Features Of HM-200 Hygronom</p> <p>Portable structure, easy to install and disassemble<br /> Able to measure the humidity of 300℃ flue gas<br /> Able to match with the large-scale system for measurement or independent measurement<br /> The probe is equipped with heat tracing function to prevent condensate water from damaging probe and affecting measuring value<br /> Imported core components with high-performance index and reliability</p> <p>Technical Parameter Of HM-200 Hygronom</p> <p>Measurement rangeO2: 0~25.00%, H2O: 0~40.00% (volume ratio )<br /> SensorFrequency conversion icon oxygen sensor (2)<br /> Accuracy0 ~ 1% O2: ± 1.5% FS<br /> 0~25%  O2:±1.5% of measured value<br /> 0-40.00% H2O: ± 1% FS<br /> Stability0 ~ 1% O2: ± 1.5% FS / 7d<br /> 0~25%  O2:±1.5%/7d of measured value<br /> 0 ~ 40.00% H2O: ± 1% FS / 7d<br /> Response timeT90 < 30s<br /> Sensor life>2 years (under normal use)<br /> Transmitter life>5 years (under normal use)<br /> Power supply24VDC<br /> Instrument weightNet weight about 2.25kg  (include operation panel)<br /> Ambient temperatureTransmitter: -10°C~+50°C<br /> Probe: 0~300℃  (except probe cable)<br /> Ambient humidity<85%RH<br /> Power consumptionMaximum about 35VA (heating)<br /> Under normal working: 30~31W<br /> Sample gas flow(2 ~ 6) L / min<br /> Analog output (2 sets)Settable 4-20mA, 0-20mA, 0-1-5-10V, 1-5V<br /> CommunicationRs485 (standard)/RS232 (optional)</p> <p>Application Of HM-200 Hygronom</p> <p>It can be widely applied in high-temperature (300℃) gas (such as desulfuration and denitration) humidity measurement of Continuous Emission Monitoring System (CEMS), humidity measurement and control in fields including wood, building material, papermaking, chemical industry, fiber, pharmacy, textile, tobacco, vegetable and food processing. </p> <p>Hangzhou Zetian Technology is committed to the integrity, strength and quality of our air quality monitor. We're internationally recognized. Welcome you to visit us.</p> <p><a href="http://www.zetian-group.com/uploads/image/20190516/13/hm-200-moisture-analysis-module.png" rel="nofollow"><img src="http://www.zetian-group.com/uploads/image/20190516/13/hm-200-moisture-analysis-module.png" alt="hm-200-moisture-analysis-module.png" /></a></p> 2020-02-10T17:32:18+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/a9li5YRURhQ zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/a9li5YRURhQ#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/a9li5YRURhQ HM-100 High-temperature Hygronom(2020年02月17日) <p><a href="http://www.zetian-group.com/products/hm-100-high-temperature-hygronom/">http://www.zetian-group.com/products/hm-100-high-temperature-hygronom/</a></p> <p>Overview<br /> Hygronom is also called moisture meter, gas moisture meter or dew-point meter, which is used to measure the humidity of flue gas emitted by pollution source. According to measured humidity, it converts wet gas concentration into dry gas concentration. In addition, it also can be used in industrial online humidity monitoring.</p> <p>HM-100 flue gas hygronom is equipped with an internal high-precision capacitance digital temperature & humidity sensor. The installation method adopts the in-situ immersion installation. It is a self-developed product, of which, the core component is from Switzerland. Put the sensor inside stack to get in touch with flue gas. The probe needs preheating to prevent gas from condensation, which will affect the measurement of moisture in the flue gas. After gas contacts with the measurement chip, the chip will change capacitance to measure flue gas concentration.</p> <p>Features Of HM-100 High-temperature Hygronom</p> <p>• The product is convenient for installation, disassembly, and cleaning with small and compact structure<br /> • Direct and simple key operation on site <br /> • The probe is equipped with heat tracing function to prevent condensate water from damaging humicap and thermal resistance <br /> • Imported core components with high-performance index and reliability</p> <p>Technical Parameter Of HM-100 High-temperature Hygronom</p> <p>Measurement RangeH2O: 0~40.00%(volume percent)(optional)<br /> Humidity sensorResistance-capacitance<br /> Temp sensorPt100 platinum resistor<br /> Accuracy0 ~ 40.00% H2O: ± 2%<br /> Repeatability0 ~ 40.00% H2O: ± 1%<br /> Stability0 ~ 40.00% H2O: ± 1% FS / 7d<br /> Response timeT90 < 6s<br /> Sensor life>2 years (under normal use)<br /> Transmitter life>5 years (under normal use)<br /> Power supply220VAC<br /> Instrument weightAbout 10kg<br /> Power consumptionMaximum about 35VA (heating)<br /> Ambient temperatureTransmitter: -10°C~+55°C<br /> Probe: 0~180°C (except probe cable)<br /> Ambient humidity<95%RH<br /> Sample gas flow(2 ~ 6) L / min<br /> Analog output (2 sets)Temperature and humidity, 4-20mA<br /> CommunicationRs232 (standard)</p> <p>Typical Application Of HM-100 High-temperature Hygronom</p> <p>1.High-temperature humidity measurement in exhaust emission (CEMS) of fire coal and oil burning boiler <br /> 2.Humidity measurement in food processing<br /> 3.Humidity measurement in wood, building material, and papermaking industry<br /> 4.Humidity measurement in fields of chemical industry and fiber<br /> 5.Humidity measurement under high temperature of open width dyeing in dyeing & printing industry</p> <p>Hangzhou Zetian Technology is committed to the integrity, strength and quality of our water quality testing products. We're internationally recognized. Welcome you to visit us.</p> <p><a href="http://www.zetian-group.com/uploads/image/20190516/13/hm-100-humidity-analyzer.png" rel="nofollow"><img src="http://www.zetian-group.com/uploads/image/20190516/13/hm-100-humidity-analyzer.png" alt="hm-100-humidity-analyzer.png" /></a></p> 2020-02-10T17:31:33+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/kje1IM7lUid zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/kje1IM7lUid#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/kje1IM7lUid FT-2000P Portable FTIR Gas Analyzer(2020年02月16日) <p><a href="http://www.zetian-group.com/products/ft-2000p-portable-ftir-gas-analyzer/">http://www.zetian-group.com/products/ft-2000p-portable-ftir-gas-analyzer/</a></p> <p>Overview<br /> Based on FTIR technology, FT-2000P portable gas analyzer can continuously monitor various kinds of components in the emission, such as SO2, NOx(NO, NO2),CH4, NH3, HCl, HF, CO, CO2, O2, H2O. According to actual measuring need, it can be extended to measure other components, like SO3, N2O and etc. This portable system mainly comprises FTIR analyzer and sampling probe. It has features of high measurement accuracy, wide dynamic range and low detection limit.</p> <p>Feature Of FT-2000P Portable FTIR Gas Analyzer</p> <p>Warming up is no required for the analyzer to realize fast measurement;<br /> Applicable for high humidity and dust occasion;<br /> Optical length up to 13m, extremely low detection limit, high range dynamics, satisfy the monitoring of small emission limit;<br /> By applying OLS and PLS techniques and selecting, interference from H2O or others can be effectively eliminated;<br /> Quick site sampling, analysis and easy operation.</p> <p>Application Of FT-2000P Portable FTIR Analyzer</p> <p>Apply to dust and noise online monitoring in construction sites, roads, residential, factory sector, tourism, waste incineration plants and other construction sites and production situations.<br /> Specification Of FT-2000P Portable FTIR Gas Analyzer</p> <p>principle:fourier transform infrared spectroscopy (FTIR)<br /> Range:SO2: (0 ~ 75) mg / m3<br /> NO: (0 ~ 200) mg / m3<br /> NO2: (0 ~ 40) mg / m3<br /> NOx: (0~200) mg/m3<br /> CO: (0 ~ 75) mg / m3<br /> H2O: (0 ~ 40)%<br /> CH4: (0 ~ 20) mg / m3<br /> NH3: (0 ~ 10) mg / m3<br /> HCl: (0 ~ 15) mg / m3<br /> HF: (0 ~ 10) mg / m3<br /> CO2: (0 ~ 20) mg / m3<br /> Pretreatment Method:condensation dewatering/whole process high temperature (optional)<br /> Repeatability:≤2%<br /> Zero Drift:≤±2%F.S./24h<br /> Span Drift:≤±2%F.S./24h<br /> Sampling Flow:(1.5 ± 0.5) L / min<br /> Response Time:≤90s (T90)<br /> Enclosure Protection:IP41<br /> Working Temp.:0 ~ 45 ℃<br /> Working Pressure:80kPa ~ 106kPa<br /> Humidity:0~95%RH<br /> Communication:RS232&USB</p> <p>Hangzhou Zetian Technology is committed to the integrity, strength and quality of our air quality monitor. We're internationally recognized. Welcome you to visit us.</p> <p><a href="http://www.zetian-group.com/uploads/image/20190708/19/ft-2000p-environmental-quality-monitoring-system.jpg" rel="nofollow"><img src="http://www.zetian-group.com/uploads/image/20190708/19/ft-2000p-environmental-quality-monitoring-system.jpg" alt="ft-2000p-environmental-quality-monitoring-system.jpg" /></a></p> 2020-02-10T17:30:57+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/CbEzpXk2wir zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/CbEzpXk2wir#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/CbEzpXk2wir EM-5P Portable Flue Gas Analyzer(2020年02月15日) <p><a href="http://www.zetian-group.com/products/em-5pportablefluegasanalyzer/">http://www.zetian-group.com/products/em-5pportablefluegasanalyzer/</a></p> <p>Overview<br /> EM-5P portable gas monitoring system mainly consists of gas monitoring sensors (SO2, NOx, CO, CO2), sample conditioning unit, sampling unit and heat tracing pipe. The main structural parts include gas sampler and pipeline, sample preconditioning unit and gas analyzer. It is equipped with android<br /> touch screen, having big data storage; with multi-port output; It also has a micro printer for real-time monitoring data.</p> <p>Feature Of EM-5P Portable Flue Gas Analyzer</p> <p>Low detection limit and temperature-drift;<br /> Getting NOx by directly measuring NO and NO2 which without NO2→NO converter;<br /> Not affected by the interference of background elements such as dust and H2O;<br /> No optical moving parts, high reliability, no interference to the measurement by field;<br /> Good portability and mobility.</p> <p>Application Of EM-5P Portable Flue Gas Analyzer</p> <p>Apply to multi-level environmental monitoring station, the third party inspection agencies, online analysis instrument production/sales/operations business who do the acceptance of environmental protection, emergency detection, instrument calibration, polluters audits to the industrial flue gas emissions occasions of coal-fired power plants, gas power plants, iron and steel plants, and laboratory gas test, etc.<br /> Specification Of EM-5P Portable Flue Gas Analyzer</p> <p>Analyzer mode:Normal Temperature-Condensation Water Removal/High Temperature-Full Temperature<br /> Principle:UV DOAS (SO2, NO), electrochemistry (O2), electrochemistry/TD-LAS (CO), infrared (CO2)<br /> Response Time:≤90s (T90)<br /> Warm-up Time:normal temperature 10 minutes/high temperature 40 minutes<br /> Power Supply:220VAC±22V, normal temperature 50W/high temperature 350W<br /> Range:0 ~ 50 ~ 1500mg / m3 (SO2 / NO / NO2), 0 ~ 25% (O2), 0 ~ 500 ~ 10000ppm (CO), 0 ~ 65% (CO2)<br /> Linearity Error:≤2%F.S.<br /> Zero Drift:≤±2%F.S./24h<br /> Span Drift:≤±2%F.S./24h<br /> Working Temp.:5 ℃ ~ 45 ℃<br /> Working Humidity:0~85%RH<br /> Dimension:498mm × 182mm × 236mm<br /> Weight:about 12kg</p> <p>Zetian is one of the most professional portable flue gas analyzer suppliers in China. Hangzhou Zetian Technology is committed to the integrity, strength and quality of our water quality testing products. We're internationally recognized. Welcome you to visit us.</p> <p><a href="http://www.zetian-group.com/uploads/image/20190708/18/em-5pportablefluegasanalyzer.jpg" rel="nofollow"><img src="http://www.zetian-group.com/uploads/image/20190708/18/em-5pportablefluegasanalyzer.jpg" alt="em-5pportablefluegasanalyzer.jpg" /></a></p> 2020-02-10T17:30:16+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/kR5MXYboPMq zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/kR5MXYboPMq#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/kR5MXYboPMq EM-5 Flue Gas Analyzer(2020年02月14日) <p><a href="http://www.zetian-group.com/products/em-5-flue-gas-analyzer/">http://www.zetian-group.com/products/em-5-flue-gas-analyzer/</a></p> <p>Overview<br /> EM-5 series flue gas analyzer is a series of self-developed gas analysis products for online gas analysis of domestic as well as foreign environmental protection and industrial control. Based on UV Differential Optical Absorption Spectroscopy (DOAS) technology and chemometrics algorithm (PLS), it is able to measure the gas concentration of SO2, NO, NO2, O2, NH3, Cl2, O3, H2S, Ch3 and etc. With features of high measurement accuracy, high reliability, fast response time, wide application scope, it can be widely applied in occasions of environment online monitoring, industrial process control, safety monitoring and etc.<br /> Depended on years of flue gas analyzer research experience and combined with practical experience of thousands of successful application cases, the analyzer has derived multiple types (standard type, low emission type, ultra-low emission type, and customized type) to meet different index requirements in different working condition.</p> <p>UV DOAS technology. The optical technology platform consists of a light source, gas chamber, optical fiber and spectrograph (including the diaphragm, a holographic grating, linear array detector) and other optical components.</p> <p>Ultraviolet light emitted by light source enters the gas chamber by an optical window and absorbed by measured sample gas flowed through the gas chamber. The light carrying sample absorption information will be gathered by the lens and coupled into an optical fiber and then transmits into spectrometer through fiber. After light splitting and photo-voltaic conversion, the gas absorption spectrum is obtained.</p> <p>The corresponding component concentration in the gas can be calculated by analyzing the spectrum.<br /> Note: the difference among standard analyzer, low emission analyzer, and ultra-low analyzer is the different optical path length of gas chamber: for standard analyzer, it adopts dual lens collimation system with 0.25m optical path; for low emission analyzer, it adopts multiple return structure with 1m optical path; for ultra-low emission analyzer, it uses white cell structure.</p> <p>Features Of EM-5 continuous flue gas analyzer</p> <p>High measurement accuracy<br /> Minimum detection limit of SO2, NO, NO2 can reach 1mg/m3  (15m optical path)<br /> Ultraviolet has no moisture absorption, undisturbed by moisture and dust<br /> No cross interference between measured gases ( refer to table 1)<br /> Measure NO and NO2 simultaneously without converter<br /> Low detection limit</p> <p>Measuring gas<br /> InterferenceSO2NONO2O2<br /> SO2 (500ppm)/<1ppmnono<br /> NO (500ppm)no/nono<br /> NO2 (500ppm)no<1ppm/no<br /> H2O (no dew)nononono<br /> CO (1000ppm)nononono<br /> CO2 (20%)nononono<br /> O2 (21%)nonono/</p> <p>High reliability<br /> Small zero drift and span drift<br /> Modular design<br /> No optical moving parts, without vibration influence<br /> Strong gas chamber, low cost<br /> Automatic adjustment spectrum technology, long maintenance-free period<br /> Adopt pulse light source with 10-year service life</p> <p>Technical Parameter Of EM-5 Flue Gas Analyzer</p> <p>Measurement PrincipleUV-DOAS+PLS<br /> VersionsRegular rangeLow rangeUltra-low range<br /> RangesMy rangeMax rangeMy rangeMax rangeMy rangeMax range<br /> ComponentSO20-300ppm0-3000ppm0-100ppm0-300ppm0-50ppm0-100ppm<br /> NO0-300ppm0-3000ppm0-100ppm0-300ppm0-50ppm0-100ppm<br /> NO20-500ppm0-4000pp0-300ppm0-1000ppm0-100ppm0-200ppm<br /> O2 (ECD or ZrO2)0-5%0-25%0-5%0-25%0-5%0-25%<br /> Linearity≤±3%F.S.<br /> Repeatability≤2%<br /> Zero Drift≤ ± 2% FS / 7d<br /> Span Drift≤ ± 2% FS / 7d<br /> Response Time(T90)≤50s<br /> Working Temperature-20 ℃ ~ + 50 ℃<br /> Preheating TimeNo preheating20min40min<br /> Sample Gas InterfaceΦ6 Bi-Lok<br /> Sample Gas FlowRange: (0.5 ~ 2) L / min, fluctuation < 25%<br /> Sample Gas PressureCurrent ambient pressure ±0.1Bar<br /> Sample Gas Temp.0 ℃ ~ + 50 ℃<br /> Sample Gas HumidityNo condensation (under sample gas temperature)<br /> 4-20mA Input3 , configurable, 100Ω load<br /> 4-20mA Output5, output content can be configured, maximum load capacity ≤800Ω<br /> Switching value Input6 , configurable<br /> Relay Output14, output content can be configured. DC30V2A<br /> Digital I / O1×Rs232, 1×Rs485 (Support Modbus protocol)<br /> Installation Method19’ panel<br /> Supply Voltage220VAC ± 10%<br /> Rated PowerAbout 100WAbout 120W</p> <p>Application Of EM-5 Flue Gas Analyzer</p> <p>Coal-fired power plant<br /> Cement plant<br /> Industrial furnace<br /> DeSOX process monitoring<br /> DeNOX process monitoring<br /> Waste incineration plant<br /> PVC process in chlor-alkali plant<br /> Titanium dioxide production process<br /> Sulfur recovery process<br /> Natural gas purification process<br /> Methyl iodide analysis for the coal chemical industry <br /> On-line air monitoring</p> <p>Hangzhou Zetian Technology is committed to the integrity, strength and quality of our air quality monitor. We're internationally recognized. We have 5 gas analyzer for sale! To learn more about the flue gas analyser working principle, please contact us!</p> <p><a href="http://www.zetian-group.com/uploads/image/20190523/09/em-5-flue-gas-analyzer-1.jpg" rel="nofollow"><img src="http://www.zetian-group.com/uploads/image/20190523/09/em-5-flue-gas-analyzer-1.jpg" alt="em-5-flue-gas-analyzer-1.jpg" /></a></p> 2020-02-10T17:29:39+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/P5wjBspBeRG zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/P5wjBspBeRG#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/P5wjBspBeRG DPM-6000 PM Monitor PM2.5/PM10(2020年02月13日) <p><a href="http://www.zetian-group.com/products/dpm-6000-pm-monitor-pm-2.5-pm-10/">http://www.zetian-group.com/products/dpm-6000-pm-monitor-pm-2.5-pm-10/</a></p> <p>Overview<br /> Inhalable particle content is one of the most important indexes for measuring air quality. Combining years of experience in developing environment and safety monitoring instruments as well as the latest demand at home and abroad, our company has launched a new generation DPM-6000 atmospheric particulate monitor with high accuracy, reliability, stability and economy. It can measure PM10, PM2.5 and dust particles of other cut sizes, widely applied in inhalable particles concentration detection in environmental atmosphere monitoring.<br /> Principle Of DPM-6000 PM Monitor PM2.5/PM10</p> <p>The monitoring principle of the pm measuring device is mainly based on enrichment technology of atmospheric particulate and beta ray attenuation method. The instrument concentrates on particulate matters whose aerodynamic equivalent diameter is smaller than 2.5/10μm on the rolled filter membrane. The instrument adopts low-radiation 14C as a radioactive source. The emitted Beta-ray passes through the filter membrane with contaminants and will be received by the detector. The detector is composed of a photo-multiplier tube (or Geiger detector), plastic scintillator and counter. The thickness of enrichment can be analyzed quantificationally according to Beta-ray energy that detector received, then the PM2.5/10 concentration in the air can be calculated.</p> <p>Features Of DPM-6000 PM Monitor PM2.5/PM10</p> <p>The design of the gas path keeps filter paper, a radioactive source and detector immovable during enrichment and measurement, ensuring a good lower detection limit.<br /> US EPA standard beta ray attenuation method, which spares the complicated operations of TEOM, such as manually replace filter paper and weight. Compared to the light scattering method, it has higher measurement accuracy.<br /> Cutter, based on simulation verification of aerodynamics, will provide a various selection of accurate particle.<br /> Sizes: PM1, PM2.5, PM10, TSP.<br /> Sampling flow is measured by a mass flow sensor and corrected with collected ambient temperature and pressure to get the sampling flow of the field.<br /> Use C14 source which is of low-density, low activity, and long half-life to realize stable measurement. No special protection is needed. Reliable and safe.<br /> Flexible paper-pressing structure. Mechanical driving design is simple and reliable; greatly reduce paper breaking and paper jam and avoid the error caused by the moving of filter paper.<br /> The pipeline heating system is used to eliminate interference from ambient humidity and make the detector fit into sudden.<br /> Flow control system with precise closed-loop feedback; stable sampling flow and small error.<br /> Various external ports, such as RS232/RS485, 4~20mA and etc.<br /> Low maintenance frequency, once a year.</p> <p>Specification Of DPM-6000 PM Monitor PM2.5/PM10</p> <p>Measuring principleBeta ray attenuation method<br /> Performance IndexMeasuring Range0~1000μg/m3³or 0~10000μg/m3 (optional)<br /> Radioactive Source14C (carbon-14), radioactivity≤60μCi<br /> Accuracy≤5%<br /> Display Resolution1μg / m3<br /> Lower Detection Limit5μg / m3<br /> Flow Error≤±2% (generally set at 16.67L/min)<br /> Sampling Flow Stability≤±2% working point flow/24h<br /> Sampling Period≤1h (time is settable)<br /> Sampling FlowDefault 16.67L/min<br /> ParallelismPM10≤10%,PM2.5≤15%<br /> Filter Paper TapeFilter Paper TapeGlass fibre, inner diameter:40mm,width: 30mm, service time 1 month (work period 1 h)<br /> Interface For.I / ORs232, RS485, 4-20mA, GPRS (optional)<br /> Data StorageOne year<br /> Working ConditionCutting headerAmbient temperaure (-40~50)℃,  ambient pressure (80~106)kPa<br /> DetectorAmbient temperature (5-40)℃, ambient pressure (80-106)kPa,  humidity (≤90%)<br /> Power SupplyAC (220 ± 22) V, (50 ± 1) Hz<br /> Dimension & Weight483×407×322(mm) (L×W×H);  Monitor 30kg, Pump 8kg</p> <p>Application Of DPM-6000 PM Monitor PM2.5/PM10</p> <p>Inhalable particle real-time monitoring in industry,, construction, residential district and etc.<br /> Environment assessment, permission, and pollution forecast and pre-warning.<br /> Ambient air quality monitoring and mobile air monitoring experimental station.<br /> Occupational disease research, and long-term background environment research.<br /> Secondary emission monitoring (coal storage area, wharf, etc.).</p> <p>Hangzhou Zetian Technology is committed to the integrity, strength and quality of our water quality testing products. We're internationally recognized. Welcome you to visit us.</p> <p><a href="http://www.zetian-group.com/uploads/image/20190516/10/dpm-6000-pm-monitor-pm2.5-pm10.png" rel="nofollow"><img src="http://www.zetian-group.com/uploads/image/20190516/10/dpm-6000-pm-monitor-pm2.5-pm10.png" alt="dpm-6000-pm-monitor-pm2.5-pm10.png" /></a></p> 2020-02-10T17:28:59+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/A5pOs7XOjC4 zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/A5pOs7XOjC4#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/A5pOs7XOjC4 Continuous Emission Monitoring System(2020年02月12日) <p><a href="http://www.zetian-group.com/products/continuous-emission-monitoring-system/">http://www.zetian-group.com/products/continuous-emission-monitoring-system/</a></p> <p>Zetian technology is the only high and new technology company with a full set of intellectual property rights of flue gas monitoring. Its independent research and development products include ultraviolet glue gas analyzer, dust monitor, temperature pressure flow, humidity meter, HCl analyzer, HF analyzer, pretreatment system, monitoring software, etc.</p> <p>Continous emissions monitoring system(CEMS) of Zetian Technology can monitor gases, including So2, NOx, O2, dust, humidity, temperature, pressure, flow parameters, etc. It can be widely used in all kinds of component continuous monitoring situation such as boilers, industrial furnaces, incinerator emissions, etc.</p> <p>In addition, it also can monitor gases for a particular occasion such as HCl, HF, CO, CO2, NH3, H2S, Cl, VOC, etc…</p> <p>It has four basic parts: the dust monitoring subsystem, gaseous pollutants monitoring subsystem, flue gas parameter monitoring subsystem, system control and data acquisition and processing subsystem. It can monitor SO2, NOx, O2, dust, temperature, pressure, flow rate and other parameters such as HCl, HF, CO, CO2 for specific occasions. After dedusting by sampling probe, tracing by heating pipe, dehydration and cooling by two-step condensing, the measured gas is analyzed by the heated gas analysis module (TDLAS and DOAS technique).It is an effective solution to solve the technical problem that large humidity variation of the waste incineration and other occasions lead to measuring data fluctuation.</p> <p>This online stack emission monitoring system adopts difference optical absorption spectroscopy (DOAS) analysis technology to measure SO2 and NOx; electrochemical to measure O2. And temperature, pressure, flow rate are respectively measured by pressure sensors and pitot micro differential pressure method. Laser scattering method is adopted to monitor dust and high temperature capacitance for humidity. Besides of SO2 and NOx, DOAS technology can also analyzer gases NH3, Cl2, H2S, O3 and etc. If system is extended with other analysis modules, it can also analyze and measure HF, HCl, CO, CO2 and so on at the same time.</p> <p>Features of Continuous Emission Monitoring System:</p> <p>The measure lower limit of ultraviolet flue gas analyzer is as low as 1 mg/m3, and fully qualified for technical parameters in ultra-low emission monitoring measurement occasions;<br /> The latest laser forward scattering dust monitor is suitable for high humidity flue gas, light-leaking stack and low dust emission and other application points;<br /> Integration of low flow velocity of temperature pressure flow product solves the problem that normal product has inaccuracy measurement under low flow velocity of flue gas;<br /> Laser HCl analyzer, HF analyzer have passed national explosion-proof certification, and have the wide recognition in the industry;<br /> The company uses UV difference gas absorption spectrum analysis technology which is fully independent intellectual property rights, effectively avoiding interference of dust and moisture on measurement;<br /> By combining multistage dust filtration technology and regular blowing back, it effectively prevents dust blocking filters and the pipeline, as well as polluting analyzer measurement pool. It can adapt to worst environment of the high dust, high humidity, high temperature, high corrosion resistance, etc. ;<br /> Ultraviolet flue gas analyzer can simultaneously measure the parameters of SO2, NO, NO2 (Being independent from NO), O2, humidity, Nox can be obtained by direct measuring of NO and NO2 , without the converter of NO2 to NO;<br /> Simple structure, without optical moving parts, long period free from maintenance, high resistance to vibration;<br /> Advanced UV difference spectrum technology, spectrum holographic grating spectrometer, diode array detection, to obtain a complete continuous absorption spectrum, long takanami resolution to ensure low detection limit, small temperature drift, fast response time;<br /> Analyzer gas chamber is processed with the features of strong gas chamber, low cost and low impact by water and dust. The detector and the gas chamber adopts optical fiber for connection. It is easy to replace and maintenance cost is low;<br /> Completely independent research and development of the core module and algorithm, the system has strong market competitiveness;<br /> The system structure is compact with high integration, easy to transport and install.</p> <p>Zetian is one of the most professional continuous emission monitoring system suppliers in China. Hangzhou Zetian Technology is committed to the integrity, strength and quality of our air quality monitor. We're internationally recognized. Welcome you to visit us.</p> <p><a href="http://www.zetian-group.com/uploads/image/20190617/18/scem-5-continuous-emission-monitoring-system-ultra-low-hot-wet.jpg" rel="nofollow"><img src="http://www.zetian-group.com/uploads/image/20190617/18/scem-5-continuous-emission-monitoring-system-ultra-low-hot-wet.jpg" alt="scem-5-continuous-emission-monitoring-system-ultra-low-hot-wet.jpg" /></a><br /> <a href="http://www.zetian-group.com/uploads/image/20190617/18/em-5-hw-continuous-emission-monitoring-system-hot-wet.jpg" rel="nofollow"><img src="http://www.zetian-group.com/uploads/image/20190617/18/em-5-hw-continuous-emission-monitoring-system-hot-wet.jpg" alt="em-5-hw-continuous-emission-monitoring-system-hot-wet.jpg" /></a><br /> <a href="http://www.zetian-group.com/uploads/image/20190617/18/em-5-cd-continuous-emission-monitoring-system-cold-dry.jpg" rel="nofollow"><img src="http://www.zetian-group.com/uploads/image/20190617/18/em-5-cd-continuous-emission-monitoring-system-cold-dry.jpg" alt="em-5-cd-continuous-emission-monitoring-system-cold-dry.jpg" /></a><br /> <a href="http://www.zetian-group.com/uploads/image/20190617/18/ga-5000nao-denox-multiparameter-online-monitoring-system.jpg" rel="nofollow"><img src="http://www.zetian-group.com/uploads/image/20190617/18/ga-5000nao-denox-multiparameter-online-monitoring-system.jpg" alt="ga-5000nao-denox-multiparameter-online-monitoring-system.jpg" /></a><br /> <a href="http://www.zetian-group.com/uploads/image/20190617/18/ga-5000dn-denox-ammonia-slip-online-monitoring-system.jpg" rel="nofollow"><img src="http://www.zetian-group.com/uploads/image/20190617/18/ga-5000dn-denox-ammonia-slip-online-monitoring-system.jpg" alt="ga-5000dn-denox-ammonia-slip-online-monitoring-system.jpg" /></a></p> 2020-02-10T17:28:19+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/owxDz9bjKM5 zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/owxDz9bjKM5#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/owxDz9bjKM5 Continuous Emission Monitoring & Process Control(2020年02月11日) <p><a href="http://www.zetian-group.com/products/continuous-emission-monitoring-process-control/">http://www.zetian-group.com/products/continuous-emission-monitoring-process-control/</a></p> <p>What is the continuous emission monitoring system working principle? The instruments and analyzers produced by Zetian now are widely used at home and abroad. They are: UV DOAS gas analyzer, laser TDLAS gas analyzer, gas analysis module, forward/backward laser dust monitoring devices, hygroscope for high temperature, continuous emission monitoring system (CEMS), denitration escape ammonia analyzer, sulphur analyzer, trace Cl analyzer system, immersive UV broad spectrum water analyzer, ammonia nitrogen analyzer, colorimetric heavy analyzer, anodic stripping voltammetry heavy metal analyzer etc.</p> <p>After years of developing, Zetian has cooperated with and attracted many worldwide clients of online monitoring and process control, including system integrator, agents, operation and maintenance providers, equipment manufacturers, thermal power plants, sewage treatment plants, chemical plants and the like.</p> <p>What we can offer are high cost-effective intellectual cems continuous emission monitoring, analysis module /component, CEMS program sets, complete set of water quality analysis program and other similar products. OEM and ODM are acceptable for us, and we can also provide operation, maintenance and other services.</p> <p>Continuous Emission Monitoring System (CEMS) consists of particulate matter monitoring subsystem, gaseous pollutants monitoring subsystem , flue gas parameters monitoring subsystem, system control and data acquisition and processing subsystem. It can monitor gases such as SO2, NOx, O2, dust, temperature, pressure, flow rate, humidity, etc. It can also be extended for a specific occasion to monitor HCl, HF, CO, CO2, NH3, H2S, Cl2, VOC and other parameters. The measured gas passes through sampling probe for dedusting, heating tube for sampling, then goes into the gas analysis module (violet differential optical absorption spectroscopy (DOAS) for analysis measurements. It effectively solves the technical problems of dust and moisture interference on measurement, particularly in the case of low concentration measurements with an unparalleled advantage.</p> <p>It applies to the emission monitoring and process analysis of coal-fired power plant, garbage power plant, cement, glass, lime factory, ceramics factory, sinter, coke oven, the process of desulfurization and denitration technology.</p> <p>Are you looking for reliable cems analyzer manufacturers? Hangzhou Zetian Technology is committed to the integrity, strength and quality of our water quality testing products. We're internationally recognized. Welcome you to visit us.</p> <p><a href="http://www.zetian-group.com/uploads/image/20190708/20/em-5001-chlorine-continuous-monitoring-system.png" rel="nofollow"><img src="http://www.zetian-group.com/uploads/image/20190708/20/em-5001-chlorine-continuous-monitoring-system.png" alt="em-5001-chlorine-continuous-monitoring-system.png" /></a><br /> <a href="http://www.zetian-group.com/uploads/image/20190523/10/pt-500-integrated-monitor-of-stack-gas-temperature-pressure-and-velocity.jpg" rel="nofollow"><img src="http://www.zetian-group.com/uploads/image/20190523/10/pt-500-integrated-monitor-of-stack-gas-temperature-pressure-and-velocity.jpg" alt="pt-500-integrated-monitor-of-stack-gas-temperature-pressure-and-velocity.jpg" /></a><br /> <a href="http://www.zetian-group.com/uploads/image/20190523/10/lgt-106-by-pass-laser-gas-analyzer.jpg" rel="nofollow"><img src="http://www.zetian-group.com/uploads/image/20190523/10/lgt-106-by-pass-laser-gas-analyzer.jpg" alt="lgt-106-by-pass-laser-gas-analyzer.jpg" /></a><br /> <a href="http://www.zetian-group.com/uploads/image/20190523/10/dms200-dust-monitor-9.png" rel="nofollow"><img src="http://www.zetian-group.com/uploads/image/20190523/10/dms200-dust-monitor-9.png" alt="dms200-dust-monitor-9.png" /></a><br /> <a href="http://www.zetian-group.com/uploads/image/20190523/09/hm-100-humidity-analyzer.jpg" rel="nofollow"><img src="http://www.zetian-group.com/uploads/image/20190523/09/hm-100-humidity-analyzer.jpg" alt="hm-100-humidity-analyzer.jpg" /></a></p> 2020-02-10T17:27:37+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/c4NuSleWi11 zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/c4NuSleWi11#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/c4NuSleWi11 Classification of Humidity Meter Gauge(2020年02月10日) <p><a href="http://www.zetian-group.com/classification-of-humidity-meter-gauge.html">http://www.zetian-group.com/classification-of-humidity-meter-gauge.html</a></p> <p>Hair humidity meter gauge</p> <p>The length of hair and some synthetic fibers varies with the relative humidity of surrounding gases: the longer the relative humidity is, the longer the length is. Using this principle, a hair hygrometer can be made. When the length of synthetic fibers changes with the change of relative humidity, the position of the pointer will be changed by mechanical transmission mechanism. The hygrometer has simple structure and is widely used in meteorological measurement.</p> <p>Lithium humidity meter gauge</p> <p>The hygrometer has a thin layer of lithium chloride coating on its surface, which absorbs water vapor from the surrounding gas and conducts electricity. The higher the relative humidity of the surrounding gas, the higher the water absorption of lithium chloride, and the smaller the resistance between the two electrodes. Therefore, the relative humidity of the surrounding gas can be reflected by the current of the electrode. Such hygrometers are widely used in industrial processes.</p> <p>Wet-dry bulb humidity meter gauge</p> <p>Usually, a wet-dry bulb hygrometer consists of two glass thermometers located adjacent to each other. One of the thermometers is wrapped with a nylon mesh and the other end of the mesh is immersed in water. Due to the capillary effect, the mesh sleeve around the thermostat is always in a wet state. When water evaporates on the surface of the mesh sleeve, the heat absorption decreases the temperature of the mesh sleeve.</p> <p>Thus, the temperature indicated by this thermometer (called wet-bulb thermometer) is lower than that indicated by another thermometer (called dry-bulb thermometer) without a net cover. The lower the relative humidity of the surrounding gas is, the faster the net sheath evaporates water, and the greater the temperature decrease. According to the temperature difference and the dry bulb temperature, the relative humidity of the surrounding gas can be found from the reference table attached to the instrument. The hygrometer has simple structure and is mainly used for meteorological measurement and indoor air humidity measurement.</p> <p>Alumina humidity meter gauge</p> <p>Its working principle is that the alumina film can absorb water from the surrounding gas and cause the change of its capacitance and resistance. The range of change is used to express the relative humidity of the surrounding gas. This kind of hygrometer is mainly used to measure the humidity of industrial process gases. It can measure the relative humidity in a wide range.</p> <p>Hangzhou Zetian Technology is committed to the integrity, strength and quality of our air quality monitor. We're internationally recognized. Welcome you to visit us.</p> <p><a href="http://www.zetian-group.com/uploads/image/20190516/13/hm-200-moisture-analysis-module.png" rel="nofollow"><img src="http://www.zetian-group.com/uploads/image/20190516/13/hm-200-moisture-analysis-module.png" alt="hm-200-moisture-analysis-module.png" /></a><br /> <a href="http://www.zetian-group.com/uploads/image/20190516/13/hm-200c-moisture-analyzer-1.png" rel="nofollow"><img src="http://www.zetian-group.com/uploads/image/20190516/13/hm-200c-moisture-analyzer-1.png" alt="hm-200c-moisture-analyzer-1.png" /></a><br /> <a href="http://www.zetian-group.com/uploads/image/20190516/13/hm-100-humidity-analyzer.png" rel="nofollow"><img src="http://www.zetian-group.com/uploads/image/20190516/13/hm-100-humidity-analyzer.png" alt="hm-100-humidity-analyzer.png" /></a></p> 2020-02-10T17:26:48+0900 http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/qzFsH3ja7lD zetiangroup http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/qzFsH3ja7lD#comments http://pastport.jp/user/zetiangroup/timeline/HANGZHOU%20ZETIAN%20TECHNOLOGY%20CO.%2C%20LTD/event/qzFsH3ja7lD