SF6 Gas 11 KV Load Break Switch
(2023年05月31日)https://www.zhgopower.com/products/11kv-sf6-gas-load-break-switch/
The load break switch 11kv is suitable for the distribution network with the highest voltage 11kV, the rated current 630A, and the rated frequency 50/60Hz, which can break off and close the load current and overload current in the power system. The 11 KV LBS is equipped with an intelligent controller to realize the automation of the distribution system. Inquiry 11kv load break switch price.
SF6 LBS Gas 11 KV Load Break Switch Features
The operating mechanism with spring energy storage ensures fast closing and switching operation (<1000ms).
Operator place: Local/Remote.
11KV LBS equipped with an electronic controller, this sf6 load break switch can be operated locally or with FTU/RTU interface for console operation.
SF6 Gas 11 kv Load Break Switch In Pole Mounted Switch Solution
The type of high-voltage bypass type SF6 11KV LBS insulated load switch is divided into manual type and electric type, which is an engineering bypass type load switch used for the maintenance and construction of power distribution cabinet in order to make uninterrupted power supply to distribution lines. This load break switch 11kv uses SF6 gas which has outstanding insulation and arc extinguishing performance. Inquiry 11kv load break switch price. Check more pole top switches.
SF6 Gas 11KV Load Break Switch PDF Specification
Environmental Conditions for Equipment Use of SF6 Gas 11KV Load Break Switch
11 KV Load Break Switch Working Procedure
The 11KV LBS load switch that uses SF6 gas as insulation and arc extinguishing medium is called the SF6 gas load break switch. It can be used to switch and switch load current and overload current, and it can also be used to switch and switch no-load circuits, no-load transformers, and capacitors. Groups, etc., all three-position load switches with the functions of connecting, disconnecting, and grounding have the characteristics of simple structure and low price. But the load switch cannot disconnect the short-circuit current.
Intended Use of SF6 Gas 11KV Load Break Switch
The 11KV LBS SF6 load switch is an excellent load switch that many users have experienced in recent years. In addition to its long electrical life and strong braking force, it has the same advantages as the vacuum load switch. Its outstanding advantage is that it is easy to achieve three working positions (connected, disconnection and grounding), small current (inductance, capacitance) breaking, strong resistance to severe environmental conditions. It is suitable for popularization and application in urban and rural medium voltage distribution networks.
As a reliable electric power equipment company, we can offer kinds of related products for sale, if you have needs, please contact us.