Effluent Treatment of Fever Clinic under COVID-19

(2021年)

https://www.pharmasources.com/events/cphi-worldwide-2021-2086.html
"Discharge Standard of Water Pollutants for Medical Organization" (GB18466-2005) puts forward specific requirements for effluent treatment and disinfection, effluent discharge, and sludge discharge of medical institutions.

1. The effluent treatment process and disinfection requirements of medical institutions mainly include the following aspects.

Effluent from wards and non-wards of medical institutions and effluent from infectious and non-infectious wards should be diverted. Solid infectious wastes and various chemical waste liquids shall not be discarded or dumped into sewers.

Special septic tanks should be set up in infectious wards of infectious disease medical institutions and comprehensive medical institutions to collect infectious wastes such as excrement after disinfection.

All kinds of special drainage from medical institutions should be collected and treated separately before being discharged into the hospital effluent treatment station. Laboratory wastewater should be collected and treated separately according to the nature of the chemicals used.

Secondary treatment and disinfection process or advanced treatment and disinfection process should be adopted for effluent treatment in infectious disease medical institutions and tuberculosis medical institutions.

The secondary treatment and disinfection process or advanced treatment and disinfection process should be adopted when effluent discharge in comprehensive medical institutions meets the discharge standards. When implementing pretreatment standards, primary treatment or primary enhanced treatment and disinfection process should be adopted.

2. Effluent discharge requirements are divided into the following two situations:

In infectious diseases and tuberculosis medical institutions, the requirement of effluent discharge is to use chlorine-containing disinfectant for disinfection. The control requirements are as follows: the contact time of the disinfection contact pool is ≥ 1.5 h, and the total residual chlorine at the outlet of the contact pool is 6.5 ~ 10 mg/l.

In general medical institutions, the requirement of effluent discharge is to use chlorine-containing disinfectant for disinfection. The emission control standards are as follows: the contact time of the disinfection contact pool is ≥ 1h, and the total residual chlorine at the outlet of the contact pool is 3 ~ 10 mg/l.

Find high quality water purification equipment, manufacturers and suppliers at pharmasources.com - the largest b2b platform in pharmaceutical industry.

Hydroxypropyl betadex ep
Category:Water Purification Equipment
Product Name:Hydroxypropyl betadex ep
Price(USD):300.00
Company:Shandong Binzhou Zhiyuan Biotechnology Co., Ltd.

Water purification equipment product page:https://www.pharmasources.com/products/catid/water-purification-equipment-243.html

Here are some events in pharmaceutical industry:Mimg_1609050752164368.jpg!200

CPhI & P-MEC China 2021
Time:December 16-18, 2021
Country/Region:Shanghai, Shanghai, China Mainland
Venue:SNIEC, Shanghai, China
Organizer:Informa Markets, CCCMHPIE

CPhI Worldwide 2021
Time:November 09-11, 2021
Country/Region: Italy
Venue:Fiera Milano, Italy
Organizer:Informa Markets

More events, you can find here:https://www.pharmasources.com/events

コメント